Conférence Stockage Electricité ATEE 10 May 2022 – Maximilien Pary – Business Developper BESS Florent Gibet – Project manager BESS
01. BESS development overview : Dunkerque project 2 Dunkerque BESS Project - MinesParistech 21/03/22
TotalEnergies organisation CEO Patrick Pouyanné Exploration Refinery & Marketing & Gas, & Production Chemicals Services Renewables & Power Renewables EXPLORE AND PRODUCE 1 OIL AND GAS 2 GAS, RENEWABLES AND POWER 3 BIOMASS PROCESS AND MONETIZE 4 SPECIALTY CHEMICALS 5 POLYMERS 6 REFINING & PETROCHEMICALS TRANSPORT AND MARKET 7 TRADING & SHIPPING 8 PRODUCTS & SERVICES 3 Dunkerque BESS Project - MinesParistech 21/03/22
Project located in Metropolitan France overview Dunkirk I ⚫ Project in 2 phases: DK1 + DK2 25MW / 25MWh = 25MW/25MWh + 36 MW/MWh = 61MW/61MWh Operating Dunkirk II 36MW / 36MWh Operating Developper & Carling 25MW / 25 MWh hosting site Operating Grandpuits 61MW/61 43MW / 43MWh In construction MWh Technology operating EPC provider Revenue streams : Ancillary services (70%) Primary reserve : FCR Supporting Capacity market (30%) Operator Largest utility-scale …Constructed …with 0 …Strong synergies battery in Europe during COVID safety with TotalEnergies operation on grid crisis… incident… integrated model… services… 4 TotalEnergies_Renewables Division - June 2021
Project DK : Zoom on Construction Dunkirk I 25MW / 25MWh Since January 2021 PROJECT : DK1 PROJECT : DK2 ● 25MW/25 MWh ● 36MW/ 36MWh ● 11 Li-Ion SAFT Max 20 High ● 16 Li-Ion SAFT Intensium Max Dunkirk II Energy (126 modules per 20 High Energy (126 modules 36MW / 36MWh containers) per containers) Since November 2021 ● COVID19 had an important impact on planning for DK1 and DK2. 15 January August 2021 : Mars Mid- 2020 Nov.2020 Dec. 2020 ● Integrated TotalEnergies model COVI May Oct.2020 RTE First utility- 2020 D19 2020 installing Powering up First injection Certifications saved a lot of time (TotalEnergies Start component tests process scale battery site, Saft batteries …) Restart s suporting the grid in France Construction : 6 months (2 months stop) Tests & Certifications : 3 months ● "Plug and Play" solutions and technology that can be replicated on other locations ● Many technical challenges for this very first utility-scale batteries of 61MW/61MWh ● Technical intreaction with the aggregator (data collection, live 5 TotalEnergies_Renewables Division - June 2021 connexion with TSO…)
Project : DK1 : Zoom on Operation TotalEnergies Flexible All operations are 100% Asset management team Power Solutions remote following up the asset valorizing the asset on performance the market KPI Financial HSE Technical Availability ● Valorization on the ● Anomalies detected ● Energy withdrawn / ● Availability on FCR injected market FCR market ● Number of alarms by ● Auxiliary consumption ● Evolution of OPEX types and categories ● Power availability ● Costs of downtime ● Active power ● Safety indicators ● SOC Management ● IT availability ● Penalties Indicators 6 TotalEnergies_Renewables Division - June 2021
UNE CENTRALE ÉLECTRIQUE VIRTUELLE - VPP POUR RELIER PRODUCTION ET CONSOMMATION Un VPP permet d'agréger des actifs de production et de consommation pour les monétiser, en optimisant les revenus de la vente d'électricité ou des services de réseau. Les batteries jouent un rôle clé dans la construction d'un VPP ! 9 Date - Pied de page de votre présentation
UNE ARCHITECTURE DE TÉLÉCOMMUNICATION PERSONNALISÉE POUR FONCTIONNER 10 Date - Pied de page de votre présentation
SERVICES ET MARCHÉ À ADRESSER AVEC UNE BATTERIE 11 Date - Pied de page de votre présentation
MÉCANISMES D’ÉQUILIBRAGE DU RÉSEAU Trois type de réserves pour équilibrer le réseau Frequency Containment Reserve (FCR) • French Power Stock : 489 MW • Goal : Compensate the loss of the two largest powerplant Process of the reserves to balance of the group of the European Grid – 3000 MW production and consumption • Activation : under 30 sec. 15 min max. OUTPUT • Deregulated Market POWER TRESHOLD Automatic Frequency Restoration Reserves (aFRR) • French Power Stock : 500 to 1180 MW DELTA P FCR aFRR mFRR • Goal : Balance the frequency and reconstitute the FCR • Activation : Under 15 min, 2 h max. • Specificity: All the powerplant over 75 MW have to Only the mFRR can The FCR restores the provide a power for participate loss of power under a long term • Deregulated market : Open from march 2022 30s FREQUENCY aFRR brings back the frequency to its MANUAL FREQUENCY RESTORATION RESERVE nominal value l DELTA F (mFRR) • French Power Stock : 1000 MW / RR 500 MW RC • Goal : Balance the grid over the long term • Activation : under 13 mn to 24h for at least 30min 30 sec max 15 min max • Deregulated market 12 Date - Pied de page de votre présentation
FREQUENCY CONTAINMENT RESERVE (FCR) / RESERVE DE FREQUENCE Durées cumulées mensuelles de déviations de fréquence MISE EN ŒUVRE supérieures à x (pour |∆f| > 0) où inférieures à x (pour |∆f| < La réserve de puissance est la capacité de production disponible pour le gestionnaire du Besoin de régulation dès que la 0) la demande en cas d'arrêt d'une réseau dans un intervalle de temps limité afin de satisfaire Durée d'activation cumulée (min/mois) fréquence n’est plus maintenue à 50 Hz unité de production, d'une rupture dans la fourniture d'électricité, ou d'un pic de la demande. 25000,00 20000,00 40,8 Hz 49 Hz 50 Hz 51 Hz 50,2 Hz 15000,00 10000,00 5000,00 Limiter la contrainte 0,00 Possibilité de coupler -0,2 -0,18 -0,16 -0,14 -0,12 -0,1 -0,08 -0,06 -0,04 -0,02 0 0,02 0,04 0,06 avec une0,08 0,1 qui batterie 0,12 0,14 0,16 0,18 0,2 réalise la majeure Déviation de fréquence (Hz) partie du travail pour une part modérée de la rémunération. 13 Date - Pied de page de votre présentation
FCR FREQUENCY CONTAINMENT RESERVE (FCR) • Power Reserve: ± 489 MW • Objectif : Compenser la perte simultanée des deux plus grandes centrales électriques d'Europe (3000 MW). • Activation: 50 % de la puissance doit être fournie dans les 15 secondes. • Marché européen libéralisé: géré par Regelleistung • Contrainte batterie: Réserve d'énergie de 15min (à Pmax) et réactivité dans les 500ms CE QUE TOTALENERGIES VA FAIRE Initialisation du processus • Installation d'un contrôleur local pour piloter la batterie suite à l'écart de fréquence • Processus de certification RTE FCR • Mise en œuvre de la stratégie de gestion du SOC, déjà testée sur la proposition technique SAFT Fonctionnement au jour le jour La batterie réagit à l'écart de fréquence • Day-ahead FCR capacity bid on Regelleistung • Programming of the set points for RTE on TOPASE • Management of unplanned maintenance on the markets 14 Date - Pied de page de votre présentation
FREQUENCY CONTAINMENT RESERVE (FCR) 116 MW 22 MW 86 MW PAYS-BAS DANEMARK BELGIQUE Assurer la stabilité des réseaux électriques GESTION FCR Cooperation FRANCE 1428 MW ALLEMAGNE 555 MW • En France, la FCR est opérée par RTE, • Au niveau européen, les enchères sont gérées au niveau européen par la 489 MW Regelleistung. SUISSE AUTRICHE SLOVÉNIE 73 MW 15 MW 64 MW 15 Date - Pied de page de votre présentation