Material Safety Data Sheets - Immuno Concepts
←
→
Transcription du contenu de la page
Si votre navigateur ne rend pas la page correctement, lisez s'il vous plaît le contenu de la page ci-dessous
Material Safety Data Sheets Please note that this document contains a complete set of MSDS Documents assembled for your convenience. If you have any questions please contact Technical Support 1.800.251.5115 technicalsupport@immunoconcepts.com www.immunoconcepts.com Document ID # 4.14.01.007.008 Revision 5.2 Issue Date 7/23/13 Page 1
Immuno Concepts, N.A. Ltd. 9825 Goethe Road # 350 Sacramento, CA 95827 USA Telephone: 916-363-2649 MATERIAL SAFETY DATA SHEET (MSDS) - - - - - PRODUCT IDENTIFICATION - - - - - Name: RELISA® Test Systems Catalog #: 7096-01, 7096-02, 7096-09, 7096-09.Au, 7096-10, 7096-10.Au, 7096-11, 7096-12, 7096-13, 7096-15, 7096-16, 7096-17 7696-01, 7696-02, 7696-09, 7696-09.Au, 7696-10, 7696-10.Au, 7696-11, 7696-12, 7696-13, 7696-15, 7696-16, 7696-17 Custom RELISA® Test Systems Catalog Series 8000-8999. - - - - - COMPOSITION/INFORMATION ON INGREDIENTS - - - - - - This product contains human source material. All human source materials used for this product have been tested and found to be negative (not repeatedly reactive) for antibodies to Human Immunodeficiency Virus-1 (HIV-1), Human Immunodeficiency Virus-2 (HIV-2), Hepatitis C Virus (HCV) and For HEPATITIS B SURFACE ANTIGEN (HBsAG) by FDA approved methods. No test method can offer complete assurance that HIV-1, HIV- 2, HCV, HBV or other infectious agents are absent. All kit materials should be handled in the same manner as potentially infectious materials. - - - - - CHEMICAL HAZARDS IDENTIFICATION - - - - - Chemical substances present in this product, but not included in this MSDS do not meet the hazardous substance criteria in European Community Council Directive 88/379/EEC or OSHA Hazard Communication Standard 29 CFR 1910.1200 or are present in concentrations which are below that required for the preparation of an MSDS. This MSDS Contains The Following Documents: 4.14.01.007.010 MSDS for products containing Sodium Azide 4.14.01.007.011 MSDS for RELISA® Substrate Solution 4.14.01.007.012 MSDS for RELISA® Stopping Solution 4.14.01.007.013 MSDS for products containing Materials of Animal Origin - - - - - OTHER INFORMATION - - - - - The above information is believed to be correct but does not purport to be all-inclusive and shall be used only as a guide. Immuno Concepts, N.A. Ltd, shall not be held liable for any damage resulting from handling or contact with the above product. Copyright 2013, Immuno Concepts, N.A. Ltd. License granted to make unlimited paper copies for internal use only. Document ID # 4.14.01.007.008 Revision 5.2 Issue Date 7/23/13 Page 2
FICHE SIGNALÉTIQUE DE SÉCURITÉ (MSDS) - - - - - IDENTIFICATION DU PRODUIT - - - - - Nom: Systèmes De Test RELISA® Réf. Catalogue: 7096-01, 7096-02, 7096-09, 7096-09.Au, 7096-10, 7096-10.Au, 7096-11, 7096-12, 7096-13, 7096-15, 7096-16, 7096-17 7696-01, 7696-02, 7696-09, 7696-09.Au, 7696-10, 7696-10.Au, 7696-11, 7696-12, 7696-13, 7696-15, 7696-16, 7696-17 Custom RELISA® Test Systems Catalog Series 8000-8999. - - - - - COMPOSITION/INFORMATIONS RELATIVES AUX INGRÉDIENTS - - - - - - Ce produit contient des matériels dʼorigine humaine. Tous les matériels dʼorigine humaine utilisés dans la composition de ce produit ont été testés et se sont révélés négatifs (non-réactivité répétée) vis-à-vis des anticorps des Virus De Lʼimmunodéficience Humaine 1 et 2 (VIH 1 et 2), de l'anticorps du Virus De Lʼhépatite C (HCV) et de Lʼantigène De Surface De Lʼhépatite B (HBsAg), selon les méthodes approuvées par la FDA. Aucune méthode de test ne peut assurer totalement l'absence de VIH-1, VIH-2, HCV, HBV ou d'autres agents infectieux. Tous les matériels du kit doivent être manipulés de la même maniière que des matériels considérés comme potentiellement infectieux. - - - - - IDENTIFICATION DES RISQUES CHIMIQUES - - - - - Les substances chimiques présentes dans ce produit, mais non incluses dans cette Fiche Signalétique De Sécurité, ne Satisfont pas aux critères de substance dangereuse tels que définis par la Directive Du Conseil De La Communauté Européenne 88/379/CEE ou du réglement OSHA sur la Communication Des Risques 29 CFR 1910.1200 ou sont présentes à des concentrations inférieures à celles requérant lʼétablissement dʼune Fiche Signalétique De Sécurité. Cette Fiche Signalétique De Sécurité Contient Les Documents Suivants: 4.14.01.007.010 MSDS for products containing Sodium Azide 4.14.01.007.011 MSDS for RELISA® Substrate Solution 4.14.01.007.012 MSDS for RELISA® Stopping Solution 4.14.01.007.013 MSDS for products containing Materials of Animal Origin - - - - - AUTRES INFORMATIONS - - - - - Les informations susmentionnées sont supposées être correctes mais ne prétendent pas être exhaustives; elles ne doivent donc être utilisées quʼà titre indicatif. Immuno Concepts, N.A. Ltd, ne peut pas être tenue pour responsable des dommages resultant de la manipulation du produit susmentionné ou du contact avec celui-ci. Copyright 2013, Immuno Concepts, N.A. Ltd. Autorisation accordée pour la photocopie illimitée de ce document pour usage interne exclusivement. Document ID # 4.14.01.007.008 Revision 5.2 Issue Date 7/23/13 Page 3
SCHEDA DATI DI SICUREZZA (MSDS) - - - - - IDENTIFICAZIONE DEL PRODOTTO - - - - - Nome: Sistemi Di Analisi RELISA® Numero Di Catalogo: 7096-01, 7096-02, 7096-09, 7096-09.Au, 7096-10, 7096-10.Au, 7096-11, 7096-12, 7096-13, 7096-15, 7096-16, 7096-17 7696-01, 7696-02, 7696-09, 7696-09.Au, 7696-10, 7696-10.Au, 7696-11, 7696-12, 7696-13, 7696-15, 7696-16, 7696-17 Custom RELISA® Test Systems Catalog Series 8000-8999. - - - - - COMPOSIZIONE E INFORMAZIONI SUGLI INGREDIENTI - - - - - - Questo prodotto contiene materiale di origine umana. Tutti i materiali di origine umana usati per questo prodotto sono stati analizzati e trovati negativi (non ripetutamente reattivi) per gli anticorpi del Virus Dell'immunodeficienza Umana Tipo 1 (HIV-1), del Virus Della Immunodeficienza Umana Tipo 2 (HIV-2), del Virus Dellʼepatite C (HCV) e Per LʼANTIGENE DI Superficie Dellʼepatite B (HBsAG) con metodi approvati dalla FDA. Nessuna metodologia di analisi può garantire con certezza che siano assenti HIV-1, HIV-2, HCV, HBV o altri agenti infettivi. Tutti i componenti del kit vanno maneggiati secondo le stesse modalità utilizzate per i materiali potenzialmente infettivi. - - - - - IDENTIFICAZIONE DEI PERICOLI CHIMICI - - - - - Le sostanze chimiche presenti in questo prodotto, ma non comprese in questa Scheda Dati Di Sicurezza, non rispondono ai criteri sulle sostanze rischiose presenti nella Direttiva 88/379/CEE Del Consiglio Delle Comunità Europee o alla norma in material di comunicazione di pericoli OSHA (Occupational Safety and Health Administration, Amministrazione Della Sicurezza E Della Salute Occupazionale) 29 CFR 1910.1200, o sono presenti in concentrazioni inferiori a quelle richieste per la preparazione di una Scheda Dati Di Sicurezza. Questa Scheda Dati Di Sicurezza Contiene I Seguenti Documenti: 4.14.01.007.010 MSDS for products containing Sodium Azide 4.14.01.007.011 MSDS for RELISA® Substrate Solution 4.14.01.007.012 MSDS for RELISA® Stopping Solution 4.14.01.007.013 MSDS for products containing Materials of Animal Origin - - - - - ALTRE INFORMAZIONI - - - - - - Le informazioni soprariportate sono ritenute corrette, ma non si dichiara che siano esaustive e vanno usate solo come guida. La Immuno Concepts, N.A. Ltd, non sarà ritenuta responsabile per danni risultanti dal contatto con i suddetti prodotti o per il loro maneggiamento. Copyright 2013, Immuno Concepts, N.A. Ltd. È concesso il permesso per fare copie illimitate solo per uso interno. Document ID # 4.14.01.007.008 Revision 5.2 Issue Date 7/23/13 Page 4
HOJA DE DATOS DE SEGURIDAD (MSDS) - - - - - IDENTIFICACIÓN DEL PRODUCTO - - - - - Nombre: Sistemas De Análisis RELISA® Nº De Catálogo: 7096-01, 7096-02, 7096-09, 7096-09.Au, 7096-10, 7096-10.Au, 7096-11, 7096-12, 7096-13, 7096-15, 7096-16, 7096-17 7696-01, 7696-02, 7696-09, 7696-09.Au, 7696-10, 7696-10.Au, 7696-11, 7696-12, 7696-13, 7696-15, 7696-16, 7696-17 Custom RELISA® Test Systems Catalog Series 8000-8999. - - - - - COMPOSICIÓN/INFORMACIÓN SOBRE LOS COMPONENTES - - - - - - Este producto contiene materiales de procedencia humana. Todos los materiales de procedencia humana utilizados en Este producto han sido analizados en busca de anticuerpos contra el Virus De La Inmunodeficiencia Humana-1 (VIH-1), el Virus De La Inmunodeficiencia Humana 2 (VIH-2), el Virus De La Hepatitis C (VHC) y el Antígeno De Superficie De La Hepatitis B (HBsAG) con métodos homologados por la FDA, obteniendo resultados negativos (no reactivos en varias ocasiones) en todos los casos. No existe ningún método de análisis que pueda garantizar por completo la ausencia de VIH-1, VIH-2, VHC, HBV u otros agentes infecciosos. Todos los materiales del kit deben ser manipulados como si fueran potencialmente infecciosos. - - - - - IDENTIFICACIÓN DE PELIGROS QUÍMICOS - - - - - Este producto contiene sustancias químicas que no figuran en esta Hoja De Datos De Seguridad y que no cumplen los requisitos de sustancia peligrosa según la Directiva 88/37/EEC Del Consejo De La Comunidad Europea, ni la norma sobre notificación de peligros 29 CFR 1910.1200 de la OSHA, o que se encuentran en concentraciones inferiores a las necesarias para la confección de una Hoja De Datos De Seguridad. Esta Hoja De Datos De Seguridad Contiene Los Siguientes Documentos: 4.14.01.007.010 MSDS for products containing Sodium Azide 4.14.01.007.011 MSDS for RELISA® Substrate Solution 4.14.01.007.012 MSDS for RELISA® Stopping Solution 4.14.01.007.013 MSDS for products containing Materials of Animal Origin - - - - - MÁS INFORMACIÓN - - - - - Se considera que la información precedente es correcta, pero no pretende ser exhaustiva y debe servir sólo como referencia. Immuno Concepts, N.A. Ltd, no será responsable de las lesiones resultantes de la manipulación o el contacto con el producto mencionado. Copyright 2013, Immuno Concepts, N.A. Ltd. Se autoriza la impresión de un número indefinido de copias para uso interno exclusivamente. Document ID # 4.14.01.007.008 Revision 5.2 Issue Date 7/23/13 Page 5
SICHERHEITSDATENBLATT (MSDS) - - - - - PRODUKTIDENTIFIKATION - - - - - Name: RELISA® Testsysteme Katalog-Nr: 7096-01, 7096-02, 7096-09, 7096-09.Au, 7096-10, 7096-10.Au, 7096-11, 7096-12, 7096-13, 7096-15, 7096-16, 7096-17 7696-01, 7696-02, 7696-09, 7696-09.Au, 7696-10, 7696-10.Au, 7696-11, 7696-12, 7696-13, 7696-15, 7696-16, 7696-17 Custom RELISA® Test Systems Catalog Series 8000-8999. - - - - - ZUSAMMENSETZUNG / ANGABEN ZU BESTANDTEILEN - - - - - - Dieses produkt enthält material menschlichen ursprungs. Sämtliche für dieses produkt verwendeten materialien menschlichen ursprungs wurden nach von der FDA anerkannten methoden negativ (nicht wiederholt reaktiv) auf antikörper gegen Humane Immunodefizienz Virus-1 (HIV-1), Humane Immunodefizienz Virus-2 (HIV-2) und Hepatitis C Virus (HCV) sowie auf Hepatitis B Oberflächen-Antigen (HBsAG) getestet. Keine testmethode kann mit absoluter sicherheit nachweisen, dass keine HIV-1, HIV-2, HCV, HBV oder andere infektiöse agenten vorhanden sind. Alle bestandteile des kits sollten wie potenziell infektiöse materialien gehandhabt werden. - - - - - MÖGLICHE GEFAHREN - - - - - In diesem produkt vorhandene chemische substanzen, die jedoch nicht in dieses MSDS aufgenommen wurden, erfüllen nicht die kriterien nach eu-richtlinie 88/379/EEC für gefährliche substanzen oder nach OSHA Hazard Communication Standard 29 CFR 1910.1200, bzw. Liegen in konzentrationen vor, die unterhalb der anforderungen für die erstellung eines MSDS liegen. Dieses MSDS Enthält Die Folgenden Dokumente: 4.14.01.007.010 MSDS for products containing Sodium Azide 4.14.01.007.011 MSDS for RELISA® Substrate Solution 4.14.01.007.012 MSDS for RELISA® Stopping Solution 4.14.01.007.013 MSDS for products containing Materials of Animal Origin - - - - - WEITERE INFORMATIONEN - - - - - Die obigen informationen sind nach unserem dafürhalten korrekt, jedoch nicht allumfassend, weshalb sie nur als richtlinie gedacht sind. Immuno Concepts, N.A. Ltd, übernimmt keine haftung für schäden jeder art, die aus der handhabung dieses produkts oder einem kontakt mit diesem produkt resultieren. Copyright 2013, Immuno Concepts, N.A. Ltd. Eine erlaubnis zum anfertigen beliebig vieler kopien für den internen gebrauch wird hiermit erteilt. Document ID # 4.14.01.007.008 Revision 5.2 Issue Date 7/23/13 Page 6
INFORMATIONSBLAD OM MATERIALSÄKERHET (MSDS) - - - - - PRODUKTIDENTIFIERING - - - - - Namn: RELISA® Testsystem Katalognr: 7096-01, 7096-02, 7096-09, 7096-09.Au, 7096-10, 7096-10.Au, 7096-11, 7096-12, 7096-13, 7096-15, 7096-16, 7096-17 7696-01, 7696-02, 7696-09, 7696-09.Au, 7696-10, 7696-10.Au, 7696-11, 7696-12, 7696-13, 7696-15, 7696-16, 7696-17 Custom RELISA® Test Systems Catalog Series 8000-8999. - - - - - SAMMANSÄTTNING/INFORMATION OM INGREDIENSER - - - - - - Den här produkten innehåller material av humant ursprung. Allt material av humant ursprung som använts i den här produkten har testats med fda-godkända metoder och visat sig vara negativt (inte upprepande reaktivt) för antikroppar mot Humant Immunbristvirus-1 (HIV-1), Humant Immunbristvirus-2 (HIV-2), Hepatit C-Virus (HCV) och Hepatit B Ytantigen (HBsAG). Ingen testmetod kan helt garantera att HIV-1, HIV-2, HCV, HBV eller andra smittämnen inte förekommer. Allt satsmaterial bör hanteras som potentiellt smittsamt. - - - - - IDENTIFIERING AV KEMISKA RISKER - - - - - Kemiska ämnen som förekommer i denna produkt, men som inte tas upp i detta Informationsblad Om Materialsäkerhet (MSDS) uppfyller inte kriterierna för riskabla ämnen enligt Europarådets Direktiv 88/379/EEC eller OSHA Riskkommunikationsstandard 29 CFR 1910.1200, eller förekommer i koncentrationer som understiger de nivåer där det krävs att ett MSDS produceras. Detta MSDS Innehåller Följande Dokument: 4.14.01.007.010 MSDS for products containing Sodium Azide 4.14.01.007.011 MSDS for RELISA® Substrate Solution 4.14.01.007.012 MSDS for RELISA® Stopping Solution 4.14.01.007.013 MSDS for products containing Materials of Animal Origin - - - - - ÖVRIG INFORMATION - - - - - Ovanstående information anses vara korrekt, men gör inte anspråk på att vara heltäckande och skall därför endast användas som vägledning. Immuno Concepts, N.A, Ltd, kan inte ställas till svars för skador som uppkommer till följd av hantering eller kontakt med ovanstående produkt. Copyright 2013, Immuno Concepts, N.A. Ltd. Tillstånd beviljas för obegränsat antal papperskopior för internt bruk. Document ID # 4.14.01.007.008 Revision 5.2 Issue Date 7/23/13 Page 7
Immuno Concepts, N.A. Ltd. 9825 Goethe Road # 350 Sacramento, CA 95827 USA Telephone: 916-363-2649 MATERIAL SAFETY DATA SHEET (MSDS) SECTION 1. -‐ -‐ -‐ -‐ -‐ -‐ -‐ -‐ -‐ PRODUCT IDENTIFICATION-‐ -‐ -‐ -‐ -‐ -‐ -‐ -‐ -‐ -‐ Name and Catalog #: ANCA Test System Conjugates, Controls and Diluents: 10009-11, 10021-11, 10021-12,10026-11, 10026-12, 10031, 10100 ANA, ANA-Ro and IgG ANA-Ro Test System Conjugates and Controls: 2009, 2009CS, 2009-Ro, 2009G-Ro, 2009GCS-Ro, 2075, 2075CS, 2075-Ro, 2075G-Ro, 2075GCS-Ro, 2021, 2022, 2023, 2025, 2026, 2027, 2029, 2031, 2035, 2035-Ro, 2037, 2041 nDNA Test Systems Conjugates and Controls: 3009, 3009G, 3075, 3075G, 3021, 3026, 3031 Auto ID® Autoantibody Test Systems Plates and Reagents: 7010, 6001, 6002, 6004, 6005, 6050, 7001, 7002, 7003 Universal Mounting Medium: 1111, 1111C Universal Counterstain (0.5% Evanʼs Blue): 1105 Serum Diluent: 100, 200, 500, 1000 ANA Sample Diluent: 20100 PSITS Patient Sample: 1800. FITC Microbead QC Slide: 1900. Hazard: Sodium Azide (0.09%) used as a preservative. The full MSDS on Sodium Azide (NaN3) is given below. SECTION 2. -‐ -‐ -‐ -‐ -‐ COMPOSITION/INFORMATION ON INGREDIENTS -‐ -‐ -‐ -‐ -‐ -‐ CAS #: 26628-22-8 MF: NaN3 EC NO: 247-852-1 Synonyms: Azide, Sodium * Azoture De Sodium (FRENCH) * Azydek Sodu (POLISH) * Kazoe * Natriumazid (GERMAN)* Natriummazide (DUTCH) * Nci-C06462 * Nemazyd * Nsc 3072 * Rcra Waste Number P105 * Smite * Sodium Azide (ACGIH) * Sodium, Azoture De (FRENCH) * Sodium, Azoturo Di (ITALIAN) * U-3886 * Document ID # 4.14.01.007.008 Revision 5.2 Issue Date 7/23/13 Page 8
SECTION 3. -‐ -‐ -‐ -‐ -‐ -‐ -‐ -‐ -‐ -‐ HAZARDS IDENTIFICATION -‐ -‐ -‐ -‐ -‐ -‐ -‐ -‐ -‐ Label Precautionary Statements • Highly toxic (USA) • Very toxic (EU) • May cause heritable genetic damage. • Very toxic by inhalation, in contact with skin and if swallowed. • Contact with acids liberates very toxic gas. • Heating may cause an explosion. • Readily absorbed through skin. • Target Organ(s): Nerves, Heart • In case of accident or if you feel unwell, seek medical advice immediately (show the label where possible). • Wear suitable protective clothing, gloves and eye/face protection. • Do not breathe dust. SECTION 4. -‐ -‐ -‐ -‐ -‐ -‐ -‐ -‐ -‐ -‐ FIRST-‐AID MEASURES-‐ -‐ -‐ -‐ -‐ -‐ -‐ -‐ -‐ -‐ -‐ • If swallowed, wash out mouth with water provided person is conscious. • Call a physician immediately. • If inhaled, remove to fresh air. If not breathing, give artificial respiration. If breathing is difficult, give oxygen. • In case of skin contact, flush with copious amounts of water for at least 15 minutes, remove contaminated clothing and shoes. Call a physician. • In case of contact with eyes, flush with copious amounts of water for at least 15 minutes. Assure adequate flushing by separating the eyelids with fingers. Call a physician. SECTION 5. -‐ -‐ -‐ -‐ -‐ -‐ -‐ -‐ -‐ FIRE FIGHTING MEASURES -‐ -‐ -‐ -‐ -‐ -‐ -‐ -‐ -‐ -‐ Extinguishing Media • Dry chemical powder • Do not use water. Special Firefighting Procedures • Wear self-contained breathing apparatus and protective clothing to prevent contact with skin and eyes. Unusual Fire And Explosions Hazards • Emits toxic fumes under fire conditions. • Container explosion may occur under fire conditions. SECTION 6. -‐ -‐ -‐ -‐ -‐ -‐ -‐ -‐ ACCIDENTAL RELEASE MEASURES-‐ -‐ -‐ -‐ -‐ -‐ -‐ -‐ -‐ • Wear self-contained breathing apparatus, rubber boots and heavy rubber gloves. • Sweep up, place in a bag and hold for waste disposal. • Avoid raising dust. • Ventilate area and wash spill site after material pickup is complete. • Evacuate area. Document ID # 4.14.01.007.008 Revision 5.2 Issue Date 7/23/13 Page 9
SECTION 7. -‐ -‐ -‐ -‐ -‐ -‐ -‐ -‐ -‐ -‐ HANDLING AND STORAGE-‐ -‐ -‐ -‐ -‐ -‐ -‐ -‐ -‐ -‐ -‐ Refer to Section 8. SECTION 8. -‐ -‐ -‐ -‐ -‐ -‐ EXPOSURE CONTROLS/PERSONAL PROTECTION-‐ -‐ -‐ -‐ -‐ -‐ • Safety shower and eye wash. • Use only in a chemical fume hood. • Wash contaminated clothing before reuse. • Wash thoroughly after handling • Do not breathe dust. • Do not get in eyes, on skin, on clothing. • Avoid prolonged or repeated exposure. • NIOSH/MSHA-approved respirator • Compatible chemical-resistant gloves • Chemical safety goggles. • Keep tightly closed. • Store in a cool dry place. • Explodes when heated. • Azide reacts with many heavy metals such as lead, copper, mercury, silver, gold to form explosive compounds. Copper and lead azides are more sensitive than nitroglycerine. Azide reacts with metal halides to give a range of metal azide halides, many of which are explosive. • Incompatible with Chromyl Chloride, Hydrazine, Bromine, Carbon Disulfide, Dimethyl Sulfate, and Dibromomalonitrile • Heat-sensitive. SECTION 9. -‐ -‐ -‐ -‐ -‐ -‐ -‐ PHYSICAL AND CHEMICAL PROPERTIES -‐ -‐ -‐ -‐ -‐ -‐ -‐ Physical Properties Solubility: • Water -Z26130 • Specific Gravity: 1.85 • PH: 10.0 SECTION 10. -‐ -‐ -‐ -‐ -‐ -‐ -‐ -‐ -‐STABILITY AND REACTIVITY -‐ -‐ -‐ -‐ -‐ -‐ -‐ -‐ -‐ Stability • Stable. Incompatibilities • Halogenated solvents • Avoid contact with metals • Avoid contact with acid • Acid chlorides Hazardous Combustion or Decomposition Products • Nitrogen Oxides Hazardous Polymerization • Will not occur Document ID # 4.14.01.007.008 Revision 5.2 Issue Date 7/23/13 Page 10
SECTION 11. -‐ -‐ -‐ -‐ -‐ -‐ -‐ -‐ -‐ TOXICOLOGICAL INFORMATION -‐ -‐ -‐ -‐ -‐ -‐ -‐ -‐ Acute Effects • May cause skin irritation. • May be fatal if absorbed through skin. • May cause eye irritation. • May be fatal if inhaled. • Material may be irritating to Mucous Membranes and Upper Respiratory Tract. • May be fatal if swallowed. • Exposure can cause: Nausea, Headache and Vomiting • Laboratory experiments in animals have shown Sodium Azide to produce a profound Hypotensive Effect, Demyelination of Myelinated Nerve Fibers in the Central Nervous System, Testicular Damage, Blindness, Attacks of Rigidity, Hepatic and Cerebral Effects. Chronic Effects Target Organ(s): • Nerves, Heart • Brain • May alter genetic material. RTECS #: VY8050000 • Sodium Azide Toxicity Data • ORL-WMN LDLO: 786 MG/KG MTAEEB 4,219,1989 • ORL-MAN LDLO: 29 MG/KG MTAEEB 4,219,1989 • ORL-MAN LDLO: 129 MG/KG JATOD3 20,134,1996 • ORL-WMN LDLO: 14 MG/KG JFSCAS 35,193,1990 • ORL-MAN LDLO: 143 MG/KG JTCTDW 24,339,1986 • ORL-RAT LD50: 27 MG/KG FMCHA2 - C32, 1991 • IHL-RAT LC50: 37 MG/M3 STGNBT - 173,1999 • SKN-RAT LD50: 50 MG/KG STGNBT - 173,1999 • SCU-RAT LD50: 45100 UG/KG MEPAAX 12,427,1961 • ITR-RAT LD50: 47500 UG/KG MEPAAX 12,427,1961 • ORL-MUS LD50: 27 MG/KG CLDND* • IHL-MUS LC50: 32400 UG/M3 STGNBT - 173,1999 • IPR-MUS LD50: 28 MG/KG JIHTAB 30,98,1948 • SCU-MUS LD50: 23060 UG/KG MEPAAX 12,427,1961 • IVN-MUS LD50: 19 MG/KG CLDND* • UNR-MUS LD50: 27 MG/KG BJCAAI 6,160,1952 • SKN-RBT LD50: 20 MG/KG FMCHA2 - C32, 1991 • ORL-BWD LD50: 23700 UG/KG AECTCV 12,355,1983 Target Organ Data • Brain and coverings (increased intracranial pressure) • Peripheral Nerve and sensation (spastic Paralysis with/without sensory change) • Sense organs and special senses (Mydriasis, other eye effects) • Behavioral (General Anesthetic, Somnolence, Convulsions or Effect on Seizure Threshold, Change in Motor Activity, Coma, Headache, Irritability) • Cardiac (Cardiomyopathy including Infarction, Arrythmias, pulse rate increased without fall in BP, pulse rate decreased with fall in BP, change in force of contraction, other changes) • Vascular (BP lowering not characterized in autonomic section) Document ID # 4.14.01.007.008 Revision 5.2 Issue Date 7/23/13 Page 11
• Lungs, Thorax or Respiration (Change in Trachea or Bronchi, Acute Pulmonary Edema, Dyspnae, Respiratory Stimulation, other changes) • Gastrointestinal (Hypermotility, Diarrhea) • Kidney, Ureter, Bladder (other changes) • Blood (changes in spleen) • Musculo-Skeletal (other changes) Only selected Registry Of Toxic Effects Of Chemical Substances (RTECS) data is presented here. See actual entry in RTECS for complete information. SECTION 12. -‐ -‐ -‐ -‐ -‐ -‐ -‐ -‐ -‐ ECOLOGICAL INFORMATION -‐ -‐ -‐ -‐ -‐ -‐ -‐ -‐ -‐ -‐ Data not yet available SECTION 13. -‐ -‐ -‐ -‐ -‐ -‐ -‐ -‐ -‐ DISPOSAL CONSIDERATIONS -‐ -‐ -‐ -‐ -‐ -‐ -‐ -‐ -‐ • Contact a licensed professional waste disposal service to dispose of this material. • Observe all Federal, State and Local Environmental Regulations. SECTION 14. -‐ -‐ -‐ -‐ -‐ -‐ -‐ -‐ -‐ -‐ TRANSPORT INFORMATION -‐ -‐ -‐ -‐ -‐ -‐ -‐ -‐ -‐ Contact Immuno Concepts N.A. Ltd, for transportation information. SECTION 15. -‐ -‐ -‐ -‐ -‐ -‐ -‐ -‐ -‐ REGULATORY INFORMATION -‐ -‐ -‐ -‐ -‐ -‐ -‐ -‐ -‐ -‐ European Information • EC Index No: 011-004-00-7 • Very toxic • R 28 - Very toxic if swallowed • R 32 - Contact with acids liberates very toxic gas. • R 50/53 - Very toxic to aquatic organisms, may cause long-term adverse effects in the aquatic environment. • S 28 - After contact with skin, wash immediately with plenty of soapsuds • S 45 - In case of accident or if you feel unwell, seek medical advice immediately (show the label where possible). Reviews, Standards, And Regulations • OEL=MAK • ACGIH TLV-Not Classifiable As A Human Carcinogen DTLVS* TLV/BEI 1999 • ACGIH TLV-CL 0.29 MG/M3 (Sodium Azide) DTLVS* TLV/BEI 1999 • OEL-Australia: TWA 0.1 PPM (0.3 MG/M3), JAN1993 • OEL-Austria: MAK 0.07 PPM (0.2 MG/M3), JAN1999 • OEL-Belgium: STEL 0.11 PPM (0.3 MG/M3), JAN1993 • OEL-Denmark: TWA 0.3 MG/M3, JAN1999 • OEL-Finland: TWA 0.1 PPM (0.3 MG/M3), STEL 0.3 PPM (0.9 MG/M3), JAN1999 • OEL-France: VLE 0.1 PPM (0.3 MG/M3), JAN1999 • OEL-Germany: MAK 0.07 PPM (0.2 MG/M3), JAN1999 • OEL-The Netherlands: MAC-TGG 0.1 PPM (0.3 MG/M3), JAN1999 • OEL-Norway: TWA 0.3 MG/M3, JAN1999 Document ID # 4.14.01.007.008 Revision 5.2 Issue Date 7/23/13 Page 12
• OEL-Switzerland: MAK-W 0.07 PPM (0.2 MG/M3), JAN1999 • OEL-United Kingdom: LTEL 0.1 PPM (0.3 MG/M3), STEL JAN1993 • OEL In Argentina, Bulgaria, Colombia, Jordan, Korea Check ACGIH TLV; • OEL IN New Zealand, Singapore, Vietnam Check ACGIH TLV • NIOSH REL to Sodium Azide, AS HN3-AIR: CL 0.1 PPM (SK) • NIOSH* DHHS #92-100,1992 • NOHS 1974: HZD 68820; NIS 13; TNF 877; NOS 10; TNE 5953 • NOES 1983: HZD 68820; NIS 19; TNF 3640; NOS 27; TNE 54959; TFE 38370 • EPA Genetox Program 1988, Positive: L5178Y Cells In Vitro-TK Test • EPA Genetox Program 1988, Positive: D Melanogaster Sex-Linked Lethal • EPA Genetox Program 1988, Positive: S Cerevisiae Gene Conversion • EPA Genetox Program 1988, Positive: S Cerevisiae-Forward Mutation; S Cerevisiae-Reversion • EPA Genetox Program 1988, Negative: In Vitro Cytogenetics-Human Lymphocyte • EPA Genetox Program 1988, Negative: Sperm Morphology-Mouse: In Vitro Uds-Human Fibroblast • EPA Genetox Program 1988, Negative: Trp Reversion • EPA Genetox Program 1988, Inconclusive: Carcinogenicity-Mouse/Rat; TRP Reversion • EPA TSCA Section 8(B) Chemical Inventory • EPA TSCA Section 8(D) Unpublished Health/Safety Studies On EPA Iris Database • EPA TSCA Test Submission (TSCATS) Data Base, October 2000 • NIOSH Current Intelligence Bulletin 13, 1976 • NTP Carcinogenesis Studies (GAVAGE); No Evidence: Rat • NTPTR* NTP-TR-389 1991 U.S. Information • This product is subject to Sara Section 313 reporting requirements. SECTION 16. -‐ -‐ -‐ -‐ -‐ -‐ -‐ -‐ -‐ -‐ OTHER INFORMATION-‐ -‐ -‐ -‐ -‐ -‐ -‐ -‐ -‐ -‐ -‐ -‐ The above information is believed to be correct but does not purport to be all-inclusive and shall be used only as a guide. Immuno Concepts, N.A. Ltd, shall not be held liable for any damage resulting from handling or contact with the above product. Copyright 2013, Immuno Concepts, N.A. Ltd. License granted to make unlimited paper copies for internal use only. Document ID # 4.14.01.007.008 Revision 5.2 Issue Date 7/23/13 Page 13
FICHE SIGNALÉTIQUE DE SÉCURITÉ (MSDS) SECTION 1. -‐ -‐ -‐ -‐ -‐ -‐ -‐ -‐ -‐ IDENTIFICATION DU PRODUIT-‐ -‐ -‐ -‐ -‐ -‐ -‐ -‐ -‐ -‐ Nom et Réf. Catalogue: Conjugués, Contrôles et Diluants du Système de Test ANCA: 10009-11, 10021-11, 10021-12, 10026-11, 10026-12, 10031, 10100 Conjugués et Contrôles du Système de Test ANA: 2009, 2009CS, 2009-Ro, 2009G-Ro, 2009GCS-Ro, 2075, 2075CS, 2075-Ro, 2075G-Ro, 2075GCS-Ro, 2021, 2022, 2023, 2025, 2026, 2027, 2029, 2031, 2035, 2035-Ro, 2037, 2041 Conjugués et Contrôles des Systèmes de Test ADNn: 3009, 3009G, 3075, 3075G, 3021, 3026, 3031 Lames et Réactifs des Systèmes de Test Dʼautoanticorps Auto ID®: 7010, 6001, 6002, 6004, 6005, 6050, 7001,7002, 7003 Dispositif de Montage Universel: 1111, 1111C Contre-Colorant Universel (Bleu Dʼevans 0,5%): 1105 Diluant Pour Sérum: 100, 200, 500, 1000 Diluant Pour ANA: 20100 Échantillon Patient PSITS: 1800 Lame de CQ À Microgoutte FITC: 1900 Risque: Azide De Sodium (0,09%) utilisé comme conservateur. La Fiche Signalétique De Sécurité complète de Lʼazide De Sodium (NaN3) figure ci-après. SECTION 2. -‐ -‐ -‐ -‐ -‐ COMPOSITION/INFORMATIONS RELATIVES AUX INGRÉDIENTS -‐ -‐ -‐ -‐ -‐ -‐ N° CAS: 26628-22-8 Formule Moléculaire: NaN3 N° CE: 247-852-1 Synonymes: Azide, Sodium * Azoture De Sodium (FRANÇAIS)* Azydek Sodu (POLONAIS)* Kazoe* Natriumazid (ALLEMAND)* Natriummazide (NÉERLANDAIS)* NCI-C06462* Nemazyd* NSC 3072* Numéro De Déchet RCRA P105* Smite* Azide De Sodium (ACGIH)* Sodium, Azoture De (FRANÇAIS)* Sodium, Azoturo Di (ITALIEN)* U-3886 * Document ID # 4.14.01.007.008 Revision 5.2 Issue Date 7/23/13 Page 14
SECTION 3. -‐ -‐ -‐ -‐ -‐ -‐ -‐ -‐ -‐ -‐ IDENTIFICATION DES RISQUES -‐ -‐ -‐ -‐ -‐ -‐ -‐ -‐ -‐ Mise En Garde Figurant Sur Lʼétiquette • Extrêmement toxique (E-U) • Très toxique (UE) • Peut causer des altérations génétiques héréditaires • Très toxique en cas dʼinhalation, de contact avec la peau et dʼingestion • Au contact d'un acide dégage un gaz très toxique • Risque d'explosion si chauffé • Absorbé rapidement par la peau • Organes Cibles: Nerfs, Cœur • En cas dʼaccident ou de malaise, consulter immédiatement un médecin (si possible, lui montrer lʼétiquette) • Porter un vêtement de protection approprié, des gants et un appareil de protection des yeux/du visage • Ne pas respirer les poussières SECTION 4. -‐ -‐ -‐ -‐ -‐ -‐ -‐ -‐ -‐ -‐ PREMIERS SOINS -‐ -‐ -‐ -‐ -‐ -‐ -‐ -‐ -‐ -‐ -‐ • En cas dʼingestion, rincer la bouche avec de lʼeau (seulement si la personne est consciente) • Appeler immédiatement un médecin • En cas dʼinhalation, transporter la victime hors de la zone contaminée. Si la personne ne respire pas, pratiquer la ventilation artificielle. Si la personne respire difficilement, la placer sous oxygène. • En cas de contact cutané, laver abondamment à l'eau pendant au moins 15 minutes. Retirer les vêtements et les chaussures contaminés. appeler un médecin. • En cas de contact avec les yeux, laver abondamment à l'eau pendant au moins 15 minutes, veiller à procéder à un rinçage correct en écartant les paupières avec les doigts. appeler un médecin. SECTION 5. -‐ -‐ -‐ -‐ -‐ -‐ -‐ -‐ -‐ LUTTE CONTRE L’INCENDIE -‐ -‐ -‐ -‐ -‐ -‐ -‐ -‐ -‐ -‐ Dispositifs Dʼextinction • Poudre chimique sèche • Ne pas utiliser dʼeau Procédures Spéciales De Lutte Contre Lʼincendie • Porter un appareil respiratoire autonome et des vêtements de protection afin dʼéviter le contact avec la peau et les yeux. Risques Inhabituels Dʼexplosion Et Dʼincendie • Émet des fumées toxiques en cas dʼincendie. • En cas dʼincendie, le récipient peut exploser. SECTION 6. -‐ -‐ -‐ -‐ -‐ -‐ -‐ -‐ MESURES CONTRE LES DÉVERSEMENTS ACCIDENTELS-‐ -‐ -‐ -‐ -‐ -‐ -‐ -‐ -‐ • Porter un appareil respiratoire autonome, des bottes en caoutchouc et des gants en caoutchouc épais. • Nettoyer puis placer les déchets dans un sac en vue de leur élimination. • Éviter de soulever de la poussière. • Après avoir ramassé les matériels, ventiler la zone et laver l'endroit où le déversement a eu lieu. • Évacuer la zone. Document ID # 4.14.01.007.008 Revision 5.2 Issue Date 7/23/13 Page 15
SECTION 7. -‐ -‐ -‐ -‐ -‐ -‐ -‐ -‐ -‐ -‐ MANIPULATION ET STOCKAGE-‐ -‐ -‐ -‐ -‐ -‐ -‐ -‐ -‐ -‐ -‐ Se Reporter à la Section 8 SECTION 8. -‐ -‐ -‐ -‐ -‐ -‐ CONTRÔLE DE L’EXPOSITION/PROTECTION PERSONNELLE-‐ -‐ -‐ -‐ -‐ -‐ • Douche de sécurité et bain oculaire. • À nʼutiliser que sous une hotte de captation des fumées chimiques • Laver les vêtements contaminés avant réutilisation • Se laver soigneusement après manipulation • Ne pas inhaler les poussières • Éviter le contact avec les yeux, la peau et les vêtements. • Éviter toute exposition prolongée ou répétée • Masque respiratoire adéquat approuvé par le NIOSH/MSHA. • Gants compatibles résistant aux produits chimiques • Lunettes de protection contre les produits chimiques • Conserver bien fermé • Stocker dans un endroit sec et frais. • Explose sous lʼeffet de la chaleur • Lʼazide réagit avec de nombreux métaux lourds, tels le plomb, le cuivre, le mercure, l'argent et l'or, pour former des composés explosifs. les azotures de cuivre et de plomb sont plus sensibles que la nitroglycérine. lʼazide réagit avec les halogénures métalliques pour donner une gamme dʼhalogénures dʼazotures métalliques, dont beaucoup sont explosifs. • Incompatible avec le chlorure de Chromyle, Lʼhydrazine, le Brome, le Sulfure de Carbone, le Sulfate de Diméthyle, le Dibromomalonitrile. • Sensible à la chaleur SECTION 9. -‐ -‐ -‐ -‐ -‐ -‐ -‐ PROPRIÉTÉS PHYSIQUES ET CHIMIQUES-‐ -‐ -‐ -‐ -‐ -‐ -‐ Propriétés Physiques Solubilité: • EAU -Z26130 • Gravité Spécifique: 1.85 • PH: 10.0 SECTION 10. -‐ -‐ -‐ -‐ -‐ -‐ -‐ -‐ -‐STABILITÉ ET RÉACTIVITÉ -‐ -‐ -‐ -‐ -‐ -‐ -‐ -‐ -‐ Stabilité • Stable Incompatibilités • Solvants halogénés • Éviter le contact avec les métaux • Éviter le contact avec lʼacide • Chlorures dʼacide Produits à combustion ou décomposition dangereuse • Oxydes Dʼazote Document ID # 4.14.01.007.008 Revision 5.2 Issue Date 7/23/13 Page 16
Polymérisation Dangereuse • Ne surviendra pas SECTION 11. -‐ -‐ -‐ -‐ -‐ -‐ -‐ -‐ -‐ INFORMATIONS TOXICOLOGIQUES -‐ -‐ -‐ -‐ -‐ -‐ -‐ -‐ Effets Aigus • Peut provoquer une irritation cutanée • Peut être mortel en cas dʼabsorption cutanée • Peut provoquer une irritation oculaire • Peut être en mortel en cas dʼinhalation • Les matériels peuvent être irritants pour les muqueuses et les voies respiratoires supérieures • Peut être en mortel en cas dʼingestion • Lʼexposition peut provoquer: Nausées, Maux DE Tête ET Vomissements • Les expériences sur des animaux de laboratoire ont montré que Lʼazide de Sodium provoquait un fort Effet Hypotenseur, une Démyélinisation des Fibres Nerveuses Myélinisées du Système Nerveux Central, des Lésions Testiculaires, une Cécité, des Crises Dʼhypertonie, et Qu'il Avait des Effets Hépatiques et Cérébraux. Effets Chroniques Organes Cibles: • Nerfs, Cœur • Cerveau • Peut altérer le patrimoine génétique N° RTECS: VY8050000 • Azide De Sodium Données De Toxicité • DLMIN. Femme, Voie Orale: 786 MG/KG MTAEEB 4,219,1989 • DLMIN. Homme, Voie Orale: 29 MG/KG MTAEEB 4,219,1989 • DLMIN. Homme, Voie Orale: 129 MG/KG JATOD3 20,134,1996 • DLMIN. Femme, Voie Orale: 14 MG/KG JFSCAS 35,193,1990 • DLMIN. Homme, Voie ORALE: 143 MG/KG JTCTDW 24,339,1986 • DL50, Rat, Voie Orale: 27 MG/KG FMCHA2 - C32 1991 • DL50, Rat, Inhalation: 37 MG/M3 STGNBT - 173,1999 • DL50, Rat, Voie Cutanée: 50 MG/KG STGNBT - 173,1999 • DL50, Rat, Voie Sous-Cutanée: 45100 µG/KG MEPAAX 12,427,1961 • DL50, Rat, Voie Intratrachéale: 47500 µG/KG MEPAAX 12,427,1961 • DL50, Souris, Voie Orale: 27 MG/KG CLDND* • DL50, Souris, Inhalation: 32400 µG/M3 STGNBT - 173,1999 • DL50, Souris, Voie Intrapéritonéale: 28 MG/KG JIHTAB 30,98,1948 • DL50, Souris, Voie Sous-Cutanée: 23060 µG/KG MEPAAX 12,427,1961 • DL50, Souris, Voie Intraveineuse: 19 MG/KG CLDND* • DL50, Souris, Non Rapporté: 27 MG/KG BJCAAI 6,160,1952 • DL50, Lapin, Voie Cutanée: 20 MG/KG FMCHA2 - C32 1991 • DL50, Espèce Naturelle Dʼoiseau, Voie Orale: 23700 µG/KG AECTCV 12,355,1983 Document ID # 4.14.01.007.008 Revision 5.2 Issue Date 7/23/13 Page 17
Données Des Organes Cibles: • Cerveau et Enveloppes Externes (Augmentation de la Pression Intracrânienne) • Nerf Périphérique et Sensibilité (Paralysie Spastique avec ou sans modification sensorielle) • Organes des Cinq Sens (Mydriase, autres effets oculaires) • Comportementales (Anesthésie Générale, Somnolence, Convulsions ou Effet sur le Seuil Épileptogène, modification de lʼactivité motrice, Coma, Maux DE Tête, Irritabilité) • Cardiaques (Cardiomyopathies y compris Infarctus, Arythmies, augmentation du rythme sans chute de la tension artérielle, diminution du rythme avec chute de la tension artérielle, modification de la force de contraction, autres modifications) • Vasculaires (diminution de la tension artérielle non caractérisée dans la partie végétative) • Poumons, Thorax ou Respiration (modifications de la Trachée ou des Bronches, Œdèmes Pulmonaires Aigus, Dyspnées, Stimulations Respiratoires, autres modifications) • Gastro-Intestinales (Hypermotilité, Diarrhées) • Rein, Uretère, Vessie (autres modifications) • Sang (modifications de la rate) • Musculo-Squelettiques (autres modifications) Seules des données sélectionnées du RTECS (Registry Of Toxic Effects Of Chemical Substances) sont présentées ici. Se reporter à lʼentrée correspondante du RTECS pour obtenir les informations complètes. SECTION 12. -‐ -‐ -‐ -‐ -‐ -‐ -‐ -‐ -‐ INFORMATIONS ÉCOLOGIQUES -‐ -‐ -‐ -‐ -‐ -‐ -‐ -‐ -‐ -‐ Données non encore disponibles. SECTION 13. -‐ -‐ -‐ -‐ -‐ -‐ -‐ -‐ -‐ CONSIDÉRATIONS LIÉES À L’ÉLIMINATION -‐ -‐ -‐ -‐ -‐ -‐ -‐ -‐ -‐ • Contacter un service dʼélimination des déchets professionnel agréé pour vous débarrasser des matériels. • Respecter lʼensemble des réglementations Fédérales, Nationales et Locales Relatives à Lʼenvironnement. SECTION 14. -‐ -‐ -‐ -‐ -‐ -‐ -‐ -‐ -‐ -‐ INFORMATIONS RELATIVES AU TRANSPORT -‐ -‐ -‐ -‐ -‐ -‐ -‐ -‐ -‐ Contacter Immuno Concepts N.A. Ltd, pour obtenir les informations relatives au transport. SECTION 15. -‐ -‐ -‐ -‐ -‐ -‐ -‐ -‐ -‐ INFORMATIONS RÉGLEMENTAIRES -‐ -‐ -‐ -‐ -‐ -‐ -‐ -‐ -‐ -‐ Informations Européennes • N° Dʼindex CE: 011-004-00-7 • Très toxique • R 28 - Très toxique en cas dʼingestion • R 32 - Au contact d'un acide dégage un gaz très toxique • R 50/53 - TRès toxique pour les organismes aquatiques, peut entraîner des effets néfastes à long terme pour l'environnement aquatique • S 28 - Après contact avec la peau, se laver immédiatement et abondamment avec de lʼeau savonneuse • S 45 - En cas dʼaccident ou de malaise, consulter immédiatement un médecin (si possible, lui montrer lʼétiquette) Document ID # 4.14.01.007.008 Revision 5.2 Issue Date 7/23/13 Page 18
Révisions, Normes Et Réglementations • Limite Dʼexposition Professionelle = Concentration Maximale Sur Le Lieu De Travail • ACGIH TLV-Not Classifiable As A Human Carcinogen DTLVS* TLV/BEI 1999 • ACGIH TLV-CL 0.29 MG/M3 (Sodium Azide) DTLVS* TLV/BEI 1999 • OEL-Australia: TWA 0.1 PPM (0.3 MG/M3), JAN1993 • OEL-Austria: MAK 0.07 PPM (0.2 MG/M3), JAN1999 • OEL-Belgium: STEL 0.11 PPM (0.3 MG/M3), JAN1993 • OEL-Denmark: TWA 0.3 MG/M3, JAN1999 • OEL-Finland: TWA 0.1 PPM (0.3 MG/M3), STEL 0.3 PPM (0.9 MG/M3), JAN1999 • OEL-France: VLE 0.1 PPM (0.3 MG/M3), JAN1999 • OEL-Germany: MAK 0.07 PPM (0.2 MG/M3), JAN1999 • OEL-The Netherlands: MAC-TGG 0.1 PPM (0.3 MG/M3), JAN1999 • OEL-Norway: TWA 0.3 MG/M3, JAN1999 • OEL-Switzerland: MAK-W 0.07 PPM (0.2 MG/M3), JAN1999 • OEL-United Kingdom: LTEL 0.1 PPM (0.3 MG/M3), STEL JAN1993 • OEL In Argentina, Bulgaria, Colombia, Jordan, Korea Check ACGIH TLV; • OEL In New Zealand, Singapore, Vietnam Check ACGIH TLV • NIOSH Rel To Sodium Azide, AS HN3-AIR: CL 0.1 PPM (SK) • NIOSH* DHHS #92-100,1992 • NOHS 1974: HZD 68820; NIS 13; TNF 877; NOS 10; TNE 5953 • NOES 1983: HZD 68820; NIS 19; TNF 3640; NOS 27; TNE 54959; TFE 38370 • EPA Genetox Program 1988, Positive: L5178Y Cells In Vitro-TK Test • EPA Genetox Program 1988, Positive: D Melanogaster Sex-Linked Lethal • EPA Genetox Program 1988, Positive: S Cerevisiae Gene Conversion • EPA Genetox Program 1988, Positive: S Cerevisiae-Forward Mutation; S Cerevisiae-Reversion • EPA Genetox Program 1988, Negative: In Vitro Cytogenetics-Human Lymphocyte • EPA Genetox Program 1988, Negative: Sperm Morphology-Mouse: In Vitro UDS-Human Fibroblast • EPA Genetox Program 1988, Negative: TRP REVERSION • EPA Genetox Program 1988, Inconclusive: Carcinogenicity-Mouse/Rat; TRP Reversion • EPA TSCA Section 8(B) Chemical Inventory • EPA TSCA Section 8(D) Unpublished Health/Safety Studies ON EPA Iris Database • EPA TSCA Test Submission (TSCATS) Data Base, October 2000 • NIOSH Current Intelligence Bulletin 13, 1976 • NTP Carcinogenesis Studies (GAVAGE); No Evidence: Rat • NTPTR* NTP-TR-389 1991 Informations Relatives Aux États-Unis • Ce produit est soumis aux exigences de rapport 313 de la Section Sara. SECTION 16. -‐ -‐ -‐ -‐ -‐ -‐ -‐ -‐ -‐ -‐ AUTRES INFORMATIONS-‐ -‐ -‐ -‐ -‐ -‐ -‐ -‐ -‐ -‐ -‐ -‐ Les informations susmentionnées sont supposées être correctes mais ne prétendent pas être exhaustives; elles ne doivent donc être utilisées quʼà titre indicatif. Immuno Concepts, N.A. Ltd, ne peut pas être tenue pour responsible des dommages résultant de la manipulation du produit susmentionné ou du contact avec celui-ci. Copyright 2013, Immuno Concepts, N.A. Ltd. Autorisation accordée pour la photocopie illimitée de ce document pour usage interne exclusivement. Document ID # 4.14.01.007.008 Revision 5.2 Issue Date 7/23/13 Page 19
SCHEDA DATI DI SICUREZZA (MSDS) SEZIONE 1. -‐ -‐ -‐ -‐ -‐ IDENTIFICAZIONE DEL PRODOTTO -‐ -‐ -‐ -‐ -‐ Nome E Numero Di Catalogo: Coniugati, ControllI e Diluenti del Sistema di Analisi in Degli ANCA: 10009-11, 10021-11, 10021-12, 10026-11, 10026-12, 10031, 10100 Coniugati e Controlli del Sistema di Analisi in Degli ANA: 2009, 2009CS, 2009-Ro, 2009G-Ro, 2009GCS-Ro, 2075, 2075CS, 2075-Ro, 2075G-Ro, 2075GCS-Ro, 2021, 2022, 2023, 2025, 2026, 2027, 2029, 2031, 2035, 2035-Ro, 2037, 2041 Coniugati e Controlli del Sistema di Analisi in Degli nDNA: 3009, 3009G, 3075, 3075G, 3021, 3026, 3031 Piastre e Reagenti del Sistema di Analisi Degli Autoanticorpi Auto ID®: 7010, 6001, 6002, 6004, 6005, 6050, 7001, 7002, 7003 Mezzo di Fissaggio Universale: 1111, 1111C Colorante di Contrasto Universale (Blu di Evans 0,5%): 1105 Diluente per Siero: 100, 200, 500, 1000 Diluente per ANA: 20100 Campione del Paziente PSITS: 1800. Vetrino QC (Quality Control, Controllo Qualità) con Microperle FITC (Fluorescent Isothiocyanate, Isotiocianato Fluorescente): 1900. Pericolo: Sodio Azide (0,09%) usato come conservante. di seguito è riportata la Scheda Dati Di Sicurezza per il Sodio Azide (NaN3). SEZIONE 2. -‐ -‐ -‐ -‐ -‐ COMPOSIZIONE E INFORMAZIONI SUGLI INGREDIENTI -‐ -‐ -‐ -‐ -‐ -‐ Numero di Cas: 26628-22-8 MF: NaN3 Numero ce: 247-852-1 Sinonimi: Azide, Sodio * Azoture de Sodium (FRANCESE) * Azydek Sodu (POLACCO) * Kazoe * Natriumazid (TEDESCO) * Natriummazide (OLANDESE) * NCI-C06462 * NEMAZYD * NSC 3072 * Numero Rifiuti RCRA P105 * Smite * Sodio Azide (ACGIH) * Sodio, Azoture DE (FRANCESE) * Sodio, Azide (ITALIANO) * U-3886 * Document ID # 4.14.01.007.008 Revision 5.2 Issue Date 7/23/13 Page 20
SEZIONE 3. -‐ -‐ -‐ -‐ -‐ -‐ -‐ -‐ -‐ -‐ IDENTIFICAZIONE DEI PERICOLI -‐ -‐ -‐ -‐ -‐ -‐ -‐ -‐ -‐ Indicazioni Precauzionali Riportate Sullʼetichetta • Altamente tossico (USA) • Molto tossico (UE) • Può causare danni genetici ereditari • Molto tossico se inalato, se a contatto con la pelle o se ingerito • A contatto con gli acidi libera un gas molto tossico • Se riscaldato può causare un'esplosione • È rapidamente assorbito attraverso la cute • Organi Bersaglio: Nervi, Cuore • In caso di incidente o malessere, rivolgersi immediatamente ad un medico (se possibile, mostrare lʼetichetta) • Indossare indumenti protettivi, guanti e mascherina di protezione per occhi e volto adeguati • Non respirarne le polveri SEZIONE 4. -‐ -‐ -‐ -‐ -‐ MISURE DI PRONTO SOCCORSO -‐ -‐ -‐ -‐ -‐ • In caso di ingestione, lavare la bocca con acqua, sempre che la persona sia cosciente. • Richiedere subito l'intervento medico • In caso di inalazione, condurre il soggetto all'aria aperta. in caso di arresto respiratorio, praticare la respirazione artificiale. Se la respirazione è difficile, somministrare ossigeno. • In caso di contatto con la pelle lavare abbondantemente con acqua per almeno 15 minuti. Rimuovere indumenti e scarpe contaminati. richiedere l'intervento medico. • In caso di contatto con gli occhi, lavare abbondantemente con acqua per almeno 15 minuti. eseguire un lavaggio adeguato aprendo le palpebre con le dita. richiedere l'intervento medico. SEZIONE 5. -‐ -‐ -‐ -‐ -‐ -‐ -‐ -‐ -‐ MISURE ANTINCENDIO -‐ -‐ -‐ -‐ -‐ -‐ -‐ -‐ -‐ -‐ Mezzi Di Estinzione • Polvere estinguente • Non usare acqua Speciali Procedure Antincendio • Indossare un respiratore autonomo e indumenti protettivi per evitare il contatto con la cute e gli occhi. Rischi Di Incendio Ed Esplosioni Insoliti • In caso di incendio, emette fumi tossici • In caso di incendio il contenitore può esplodere SEZIONE 6. -‐ -‐ -‐ -‐ -‐ -‐ -‐ -‐ PROVVEDIMENTI IN CASO DI DISPERSIONE ACCIDENTALE -‐ -‐ -‐ -‐ -‐ -‐ -‐ -‐ -‐ • Indossare un respiratore autonomo, stivali di gomma e guanti di gomma pesanti • Raccogliere il materiale, riporlo in un sacchetto e conservarlo per lo smaltimento dei rifiuti • Evitare di sollevare le polveri • Aerare la zona e lavare l'area contaminata dal prodotto fuoriuscito dopo averlo completamente recuperato • Evacuare lʼarea Document ID # 4.14.01.007.008 Revision 5.2 Issue Date 7/23/13 Page 21
Vous pouvez aussi lire