LHC ES - Hydraulik und Wassertechnik ORELL

 
CONTINUER À LIRE
LHC ES - Hydraulik und Wassertechnik ORELL
www.orelltec.com

                        LHC
With hydraulic motor - optimized for mobile and industrial use
              Installation and servicing manual

                SE    GB     DE     FR     ES
LHC ES - Hydraulik und Wassertechnik ORELL
OLAER/OA-Technik LHC AIR OIL COOLER |      Installation and servicing manual

                                                                       LHC                                            A       B
                                                                     AIR OIL COOLER

 1                                                                                             C                          D

                                                                 2

         1/2 A                                               B
                                                                                                                                      C
                                         1/2 A
                    LHC
                   AIR OIL COOLER

                                                                                                                                  D
          A

                                                                                                                                  A

 3                                                               4

                                                                                                    LHC        COOL
                                                                                                                   ER
                                                                                                         OIL
                                                                                                   AIR

 5                                                               6

The Professional Choice
LHC ES - Hydraulik und Wassertechnik ORELL
OLAER/OA-Technik LHC AIR OIL COOLER | Installation and servicing manual

                                          LHC
                                         AIR
                                               OIL
                                                     COOL
                                                         ER
                                                                                                LHC        COOL
                                                                                                               ER
                                                                                                     OIL
                                                                                               AIR

                            7                                                                  8

                      9                                                            10 A                             10 B

                                                               LHC        COOL
                                                                              ER
                                                                    OIL
                                                              AIR

                             11                                                           12

The Professional Choice
OLAER/OA-Technik LHC AIR OIL COOLER | Installation and servicing manual

                                              LHC
                                             AIR OIL COOLER

                                                                                                                             H        I

                          B
                                                                                                           G

                                                                          E                   F                                   H
                                      D
     A

                                  C

                                                                                                               E                  G

Komponentförteckning                          Komponentenverzeichnis                               Lista de componentes
A    Kylelement                               A           Kühlelement                              A    Radiador
B    Pluggar och gummistålbrickor             B           Stopfen und Gummistahlscheiben           B    Tapón ciego con junta metalbuna
C    Fötter                                   C           Füße                                     C    Patas
D    Fläkthus                                 D           Lüftergehäuse                            D    Caja del ventilador
E    Fläktenhet*                              E           Lüftereinheit*                           E    Ventilador completo*
F    Motorfäste                               F           Motorhalterung                           F    Suporte del motor
G    Fläktgaller                              G           Schutzgitter                             G    Rejilla de protección
H    Stödlager**                              H           Vorsatzlager**                           H    Cojinete de empuje**
I    Hydraulmotor                             I           Hydraulikmotor                           I    Motor hidráulico
*    Utförandet, fast eller löst nav,         *           Die Ausführung mit starrer oder loser    *    El asiento del ventilador, fijo o
     varierar med kylarmodell                             Nabe hängt vom Kühlermodell ab.               desmontable, dependerá del tipo
**   Finns på kylarmodell från och med        **          Ab Kühlergrösse 033 verfügbar.                de intercambiador.
     storlek 033.                                                                                  **   A partir del tamaño 033

Part list                                     Liste des composants
A    Cooler matrix                            A           Radiateur
B    Plugs and rubber steel washers           B           Bouchons et joints à lèvres
C    Support                                  C           Pieds
D    Fan housing                              D           Caisson ventilateur
E    Fan unit*                                E           Hélice complète*
F    Motor attachment                         F           Support moteur
G    Fan guard                                G           Grille ventilateur
H    Collar bearing**                         H           Contre paliers**
I    Hydraulic motor                          I           Moteur hydraulique
*    The design, fixed or detachable hub,     *           La conception, moyeu fixe ou non fixe,
     is depending on type of cooler.                      varie suivant le modèle d’échangeur.
**   Available as from size 033.              **          Disponsible dès la taille 033.
OLAER/OA-Technik LHC AIR OIL COOLER | Installation and servicing manual

                                                                                       C

                                                                                                       F

                                                                                             LHC
                                                                                            AIR OIL COOLER

                                                                                                                             D

                                                                                                                         E

                                         B

             A

                                                                  G

Tillval                                      Sonderzubehör                             Equipamientos opcionales
A Stenskydd                                  A Steinschutz                             A   Rejilla protectora para piedras
B Dammskydd                                  B Staubschutz                             B   Filtro antipolvo
C    S-Bypass ventil, enpassage*             C   S-Bypassventil, Einzeldurchlauf*      C   S-Válvula by-pass, un paso*
D T-Bypassventil, tvåpassage*                D T-Bypassventil,Doppeldurchlauf*         D   T-Válvula bypass, dos pasos*
E    Termokontakt                            E   Thermokontakt                         E   Termocontacto
*   Kan fås som tryckstyrd eller             *   Mit Drucksteuerung oder Temperatur-   *   Disponible como by-pass controlado
    temperatur- och tryckstyrd bypass.           und Drucksteuerung lieferbar.             por presión o por temperatura y
                                                                                           presión.
Tillbehör                                    Zubehör
F    Lyftöglor                               F   Hebeösen                              Accesorios
G Vibrationsdämpare                          G Vibrationsdämpfer                       F   Cáncamos de elevación
                                                                                       G Silent blocs
Options                                      Équipements en option
A Stone guard                                A Grille de protection
B Dust guard                                 B Filtre antipoussière
C   S-Bypass valve, single-pass*             C   S-Valve by-pass, 1-passe*
D T-Bypass valve, two pass*                  D T-Valve by-pass, 2-passes*
E   Thermo contact                           E   Thermocontact
*   Pressure controlled or temperature       *   Disponible comme bypass commandée
    and pressure controlled by-pass.             par pression ou par température et
                                                 pression.
Accessories
F   Lifting eye                              Accessoires
G Vibration dampener                         F   Anneaux de levage
                                             G Patins antivibratoires

The Professional Choice
OLAER/OA-Technik LHC AIR OIL COOLER | Installation and servicing manual | Svenska           1

                                                       Inledning                        2
                                                       Säkerhetsföreskrifter            2
                                                       Beskrivning                      3
                                                       Installation                     3
                                                       Handhavande                      3       SE
                                                       Förebyggande underhåll           4
                                                       Underhåll                        4
                                                       Tekniska data                    5
                                                       Försäkran om överensstämmelse    6

                                                       Introduction                     7
                                                       Safety instructions              7
                                                       Description                      8
                                                       Installation                     8
                                                       Handling                         9       GB
                                                       Preventive maintenance           9
                                                       Maintenance                     10
                                                       Technical specification         11
                                                       Declaration of conformity       12

                                                       Einleitung                      13
                                                       Sicherheitsvorschriften         13
                                                       Beschreibung                    14
                                                       Installation                    14
                                                       Bedienung                       15       DE
                                                       Vorbeugende Wartung             15
                                                       Wartung                         16
                                                       Technische Daten                17
                                                       Übereinstimmungserklärung       18

                                                       Introduction                    19
                                                       Consignes de sécurité           19
                                                       Description                     20
                                                       Installation                    20
                                                       Consignes d’emploi              21       FR
                                                       Entretien préventif             21
                                                       Entretien                       22
                                                       Caractéristiques techniques     23
                                                       Déclaration de conformité       24

                                                       Introducción                    25
                                                       Instrucciones de seguridad      25
                                                       Descripción                     26
                                                       Instalación                     26
                                                       Modo de empleo                  27
                                                                                                ES
                                                       Mantenimiento preventivo        27
                                                       Mantenimiento                   28
                                                       Características técnicas        29
                                                       Daclaración de conformidad      31

The Professional Choice
2       OLAER/OA-Technik LHC AIR OIL COOLER | Installation and servicing manual | Svenska

                                                                    Anm! Anger extra information som kan underlätta förståel-
Inledning                                                           se för, eller utförande av, ett visst moment.
Denna anvisning är avsedd att vara ett hjälpmedel vid
instal-lation, användning och underhåll av OLAER/OA-                Övergripande föreskrifter
Technik LHC-serie av luft-oljekylare.
  Förvara anvisningen så att den alltid finns till hands.             Lyft
Ersätt omedelbart en förlorad anvisning.
                                                                    
                                                                            Varning Kläm-/krossrisk. För att undvika personska-
  Läs igenom anvisningen och varningstexterna noggrant
                                                                            dor vid lyft är det viktigt att använda rätt lyftmetod.
och se till att förstå innehållet innan du använder luftolje-
                                                                    Kontrollera att den lyftanordning och de lyftdon som används
kylaren. På så sätt får du ut mesta möjliga av din luftoljeky-
                                                                    är felfria och godkända för luftoljekylarens vikt.
lare och felaktig användning undviks.
  Endast för ändamålet utbildad personal får installera,
                                                                      Installation, drift, handhavande
handha och underhålla luftoljekylaren.
                                                                      och underhåll
OLAER/OA-Technik förbehåller sig rätten till tekniska

                                                                    
ändringar.                                                                   Varning Risk för personskada. Koppla bort drivkällan
  Avsedd användning OLAER/OA-Technik LHC-serie av                            för motorn innan underhåll.
luftoljekylare är avsedd för kylning av olja i hydraulsystem
för industriella och mobila applikationer.
Garanti och reklamation Vid haveri, kontakta OLAER/
                                                                          Varning Risk för personskada. Se till att systemet är
                                                                           trycklöst innan bortkoppling av hydraulslangar och
                                                                    hydraulanslutningar.
OA-Technik ansvarar inte för luftoljekylaren efter

                                                                    
egenhändiga
                                                                           Varning Risk för allvarlig brännskada. Vid drift kan
reparationer och/eller modifieringar.                                      luftoljekylaren bli mycket varm. Vidrör ej luftolje-
                                                                    kylaren förrän den har svalnat.
Säkerhetsföreskrifter
Installatör och brukare ska känna till, förstå och beakta var-            Försiktighet Klämrisk. Luftoljekylaren kan styras via
                                                                           en termokontakt. Fläkten startar då automatiskt vid
ningar eller upplysningar som anges på dekaler, skyltar och         uppnådd inkopplingstemperatur. Var försiktig vid vistelse
i denna anvisning.                                                  nära roterande komponenter.

Varningsnivåer och uppmärksamhetstexter...
...gällande personlig säkerhet
                                                                          Försiktighet Risk för förgiftning. Förbrukad olja skall
                                                                           lämnas på där för avsedd depå för att inte orsaka ska-
                                                                    da på person, egendom eller miljö.
Uppmärksamhetstexter som har med personlig säkerhet att
göra är klassade i tre nivåer, enligt nedan, beroende på hur          Viktigt Risk för skada i hydraulsystemet. Föroreningar,
allvarliga följderna av en olycka kan bli.                          vatten och luft ökar slitage på hydraulkomponenter och kan
                                                                    orsaka haverier. Var noggrann med renhet vid ingrepp i hydraul-


      Fara anger att en olycka kommer att inträffa om före-         systemet.
      skriften inte följs. Olyckan leder till allvarlig per-
sonskada eller möjligen dödsfall.                                     Viktigt Statisk elektricitet. Fläktar alstrar statisk elektrici-
                                                                    tet. Undvik känslig utrustning (elektronik m.m.) i luftoljekyla-


        Varning anger att en olycka kan komma att inträffa          rens omedelbara närhet. Antistatiska fläktar finns att beställa.
        om föreskriften inte följs. Olyckan kan leda till all-
varlig personskada eller möjligen dödsfall.                           Anm! Använd hörselskydd vid vistelse under en längre tid
                                                                    i närheten av en driftsatt luftoljekylare.


       Försiktighet anger att en olycka kan komma att
       inträffa om föreskriften inte följs. Olyckan kan leda till
personskada.
                                                                      Varningsdekal
...gällande övrig säkerhet                                          Nedanstående dekal är fäst på luftoljekylaren vid leverans.
Uppmärksamhetstexter som har med övrig säkerhet (egen-              Ersätt skadad eller saknad dekal omedelbart.
dom, process eller omgivning) och handhavande att göra är             • Varning! Heta ytor! Använd hörselskydd! Roterande
klassade enligt följande:                                                fläkt! (art.nr. 500029 - 70x30 mm alt. art.nr. 5000291
                                                                         - 120x50 mm). Se Bild 1.
  Viktigt anger att en olycka kan komma att inträffa om
föreskriften inte följs. Olyckan kan leda till skada på egen-
dom, process eller omgivning

...gällande tilläggsinformation
Tilläggsinformation markeras enligt följande:
OLAER/OA-Technik LHC AIR OIL COOLER | Installation and servicing manual | Svenska                                               3

                                                                     Viktigt Vid montering och installation av hydraulmotorn,
Beskrivning                                                        se till att installera motorn i en ren miljö.
LHC luftoljekylare består i huvudsak av ett kylelement, en
hydraulmotor, en fläkt, ett fläkthus och ett fläktgaller.
Kylelementet och hydraulmotorn ansluts till hydraulsystemet
via hydraulslangar.                                                Anslutning av kylelement
   Olika typer av hydraulmotorer används i LHC serie av luft-      Använd hydraulslangar både till och från kylelementet. Se
oljekylare. Normal omgivningstemperatur -20 °C – 60 °C. För        till att kopplingar och slangar är dimensionerade efter sys-
generella driftsfakta, se Tekniska data.                           temets tryck, flöde, temperatur och typ av olja. Anslut hydraul-
Större kylare är utrustade med stödlager, vilket ger längre        slangarna till kylelementet enligt följande. Se Bild 4.
livslängd hos hydraulmotorn.                                          A - Inlopp
Luftoljekylaren kan utrustas med en termokontakt för tem-             B - Utlopp för modell enpassage
peraturlarm. Fläkten startar då automatiskt vid uppnådd               C - Utlopp för modell tvåpassage
inkopplingstemperatur.                                                D - Anslutning för termokontakt.
Ljudtrycksnivån kan, beroende av kylarstorlek, uppgå till 62-
93 LpA d(A) vid 1 m avstånd under normala driftsförhållan-         Dimensioner på anslutningar beror på kylelementets storlek.
den. Olämplig placering, eller drift under extrema förhållan-      Kopplingsschema. Se Bild 5.
den, kan orsaka förhöjd ljudtrycksnivå och sämre kyleffekt.
                                                                     Viktigt Kylelementet är dimensionerat för maximalt dyna-
                                                                   miskt arbetstryck 14 bar. Undvik tryckstötar när luftoljekylaren
Märkskylt                                                          installeras i systemets returledning. Om detta inte är möjligt,
                                                                   installera luftoljekylaren i ett separat kylsystem.
Luftoljekylarens märkskylt är placerad på fläkthuset. Se Bild 2.
På märkskylten finns information om:
  A - Artikelnummer                                                Anslutning av hydraulmotor
  B - Artikelbenämning                                               Viktigt Risk för skada i hydraulsystemet. Föroreningar,
  C - Serienummer                                                  vatten och luft ökar slitage på hydraulkomponenter och kan
  D - Leveransdatum (år och vecka, t.ex. 1018,                     orsaka haverier. Var noggrann med renhet vid ingrepp i hydraul-
        d.v.s. år 2010 och vecka 18).                              systemet.

  Ersätt skadad eller saknad skylt omedelbart.                        Använd hydraulslangar både till och från hydraulmotorn. Se
                                                                   till att kopplingar och slangar är dimensionerade efter syste-
                                                                   mets tryck, flöde, temperatur och typ av olja.
                                                                      Undvik trånga strypningar och slangböjar med liten radie.
Installation                                                       Dimensioner på anslutningar beror på hydraulmotorns
  Lyft                                                             storlek.


        Varning Kläm-/krossrisk. För att undvika personska-           Var noggrann vid inkoppling. Felaktig inkoppling kan ge upp-
        dor vid lyft är det viktigt att använda rätt lyftmetod.    hov till fel rotationsriktning på motor och fläkt, se skylt för
Kontrollera att den lyftanordning och de lyftdon som används       rotationsriktning. Anpassa oljeflödet till hydraulmotorn så att
är felfria och godkända för luftoljekylarens vikt.                 det maximalt tillåtna varvtalet inte överskrids. För högt varv-
                                                                   tal medför risk för haveri.
Alla luftoljekylare från och med storlek 033 är förberedda            OLAER/OA-Technik LHC luftoljekylare är normalt försedd
för lyftöglor. Lyftöglor finns att beställa som tillbehör          med externt drä-nerad hydraulmotor. Anslut hydraulmotorns
från OLAER/OA-Technik.                                             dräneringsslang direkt till tank. Maximalttryck i
                                                                   dräneringsanslutning är 5 bar.
Montering
                                                                   Elektrisk anslutning

        Försiktighet Risk för personskador. Se till att luft-
         oljekylaren alltid är ordentligt fastsatt.                Om luftoljekylaren är utrustad med termokontakt, använd relä
                                                                   om termokontakten belastas med mer än vad som är tillåtet för
Luftoljekylaren kan monteras i vilket läge som helst, stående      termokontakten.
på luftoljekylarens fötter är dock att föredra. För att uppnå
god luftgenomströmning och därmed bästa möjliga kyleffekt
och lägsta möjliga ljudtrycksnivå, lämna ett utrymme motsva-
                                                                   Handhavande
rande åtminstone halva elementhöjden (A) fritt framför och           Innan första start
bakom luftoljekylaren. Se Bild 3. Olämplig placering av luft-

                                                                   
oljekylaren, eller drift under extrema förhållanden, kan orsaka           Försiktighet Kontrollera att luftoljekylaren är ordent-
förhöjd ljudtrycksnivå och sämre kyleffekt.                               ligt fastsatt och korrekt ansluten.

The Professional Choice
4                        OLAER/OA-Technik LHC AIR OIL COOLER | Installation and servicing manual | Svenska

  Det är viktigt att använda rätt typ av olja i hydraulmotorn,    Kontrollera att:
samt att kvalitativa filter används för att erhålla god             • inga onormala ljud och vibrationer förekommer
reningsnivå.                                                        • luftoljekylaren är ordentligt fastsatt
  Säkerställ att alla slangar liksom tanken är ordentligt ren-      • kylelementet är rent, smuts försämrar kyleffekten
gjorda.                                                             • oljan i systemet håller rekommenderad renhetsnivå,
  OLAER/OA-Technik rekommenderar att:                                  byt vid behov
  1 Luftoljekylaren körs igenom med samma typ av olja               • luftoljekylaren är fri från skador, byt ut trasiga komponenter
     som används i systemet,                                        • luftoljekylaren inte läcker, åtgärda eventuellt läckage
  2 oljan filtreras innan den körs igenom kylaren.                  • varningsdekal är i gott skick, ersätt skadad eller saknad
  Se Tekniska data för rekommenderade vätskekombinationer              dekal omedelbart.
  samt rekommenderad reningsnivå.
                                                                  Rengöring
    Innan start

                                                                 
       Försiktighet Se till att enheten kan startas utan risk            Varning Risk för personskada. Koppla bort drivkällan
       för skada på person, egendom eller miljö.                         för motorn innan rengöring.
Kontrollera att:

                                                                  
  • luftoljekylarens delar inte är skadade                               Varning Risk för allvarlig brännskada. Vid drift kan
  • luftoljekylaren är korrekt ansluten                                  luftoljekylaren bli mycket varm. Vidrör ej luftolje-
  • fläkten roterar fritt (använd handkraft)                      kylaren förrän den har svalnat.
  • alla hydrauliska anslutningar är åtdragna
  • fläkthusets insida är fri från föremål som kan slungas          Luftoljekylare Vid yttre rengöring av luftoljekylaren, med
     iväg och orsaka skador på person eller egendom.              t.ex. vatten, demontera alla elanslutningar.
                                                                    Kylelement Kylelementets luftlameller rengörs enklast
    Vid start                                                     med tryckluft. Vid behov, använd högtryckstvätt med avfett-
Kontrollera att:                                                  ningsmedel. Vid högtrycksspolning måste strålen föras
  • fläktens rotationsriktning och luftflöde överensstämmer       parallellt med lamellerna. Se Bild 6.
     med indikering på dekal på fläkthuset                          Fläkthus Demontera kylelementet vid invändig rengöring
  • inga onormala ljud och vibrationer förekommer,                av fläkthuset. Insidan av fläkthuset rengörs enklast med
  • luftoljekylaren inte läcker                                   tryckluft. Vid behov, använd avfettningsmedel. Blås med
  Kontakta OLAER/OA-Technik vid användning av                     tryckluft från hydraulmotorsidan genom fläktgallret.
oljor med viskositet > 100 cSt (t.ex. tjock smörjolja).

  För att skydda kylelementet, använd bypassventil vid kall-
start/tjock olja. Se LHC broschyr.
                                                                  Underhåll
                                                                  OLAER/OA-Technik ansvarar inte för konsekvenser efter
                                                                  egenhändigt, av kunden, utförda reparationer eller
    Under drift
                                                                  modifieringar.

       Varning Risk för allvarlig brännskada. Vid drift kan
       luftoljekylaren bli mycket varm. Vidrör ej luftoljekyla-     Demontering av kylelement
ren förrän den har svalnat.

Maximalt tillåten oljetemperatur i kylelementet är 120 °C. Se           Varning Risk för allvarlig brännskada. Vid drift kan
                                                                         luftoljekylaren bli mycket varm. Vidrör ej luftoljekyla-
                                                                  ren förrän den har svalnat.
Teknisk data för maximalt tillåten oljetemperatur i motorn.
  Kylelementet är dimensionerat för maximalt dynamiskt

                                                                  
arbetstryck 14 bar.                                                      Varning Risk för personskada. Koppla bort drivkällan
  Undvik att använda hydraulmotorn under en längre tid                   för motorn innan underhåll.
med lågt varvtal och högt tryck.
                                                                    1 Stäng av systemet.
  Anm! Använd hörselskydd vid vistelse under en längre tid          2 Koppla bort drivkällan för motorn.
i närheten av en driftsatt luftoljekylare.                          3 Se till att systemet är trycklöst.
                                                                    4.Stäng oljeanslutningarna.
                                                                    5 Koppla bort hydraulslangarna.
Förebyggande underhåll                                              6 Skruva loss skruvarna med brickor som fäster
De viktigaste underhållsåtgärderna är de förebyggande åt-             kylelementet i fläkthuset. Se Bild 7.
gärderna som brukaren utför med jämna intervaller.                  7 Lyft bort kylelementet.

  Viktigt Risk för skada i hydraulsystemet. Föroreningar,           Montering av kylelement
vatten och luft ökar slitaget på hydraulkomponenterna och           1 Lyft kylelementet på plats.
kan orsaka haverier. Var noggrann med renhet vid ingrepp i          2 Skruva fast kylelementet i fläkthuset. Se Bild 7.
hydraulsystemet.                                                    3 Anslut hydraulslangarna till kylelementet. Se Bild 4.
OLAER/OA-Technik LHC AIR OIL COOLER | Installation and servicing manual | Svenska                                                5

  4 Koppla till drivkällan för motorn.                                   motorfästet i fläkthuset. Se Bild 8.
  5 Utför åtgärder enligt Innan start och Vid start.              6      Kontrollera att fläkten är centrerad och roterar fritt
                                                                         (använd handkraft). Vid behov justera placeringen av
  Demontering av hydraulmotor och fläkt                                  fläktgallret och motorn.
                                                                  7      Se till att alla skruvar är åtdragna.


       Varning Risk för allvarlig brännskada. Vid drift kan       8      Koppla till drivkällan för motorn.
       luftoljekylaren bli mycket varm. Vidrör ej luftolje-       9      Utför åtgärder enligt Innan start och Vid start
kylaren förrän den har svalnat.

      Varning Risk för personskada. Koppla bort drivkällan
       för motorn innan underhåll.
                                                                  Tekniska data
                                                                      Kylelement
  Viktigt Risk för skada i hydraulsystemet. Föroreningar,             Maximalt statiskt arbetstryck                         21 bar
vatten och luft ökar slitaget på hydraulkomponenterna och             Maximalt dynamiskt arbetstryck                       14 bar*
kan orsaka haverier. Var noggrann med renhet vid ingrepp i            Värmeöverföringstolerans                               ±6%
hydraulsystemet.                                                      Maximalt tillåten oljetemperatur                      120 °C
                                                                      Maximal kyleffekt                                    160 kW
  Anm! Vissa modeller har fast nav, se Bild 9, andra model-           * Testat enligt ISO/DIS 10771-1
ler har löst nav, se Bild 10 A och Bild 10 B. Fläkten hos
modell LHC-033 och större är balanserad tillsammans med               Vätskekombinationer
navet vid leverans.                                                   Mineralolja (enligt DIN 51524)                      HL/HLP
                                                                      Olja/vattenemulsion (enligt CETOP RP 77H)          HFA, HFB
  1 Stäng av systemet.                                                Vattenglykol (enligt CETOP RP 77H)                      HFC
  2 Koppla bort drivkällan för motorn.                                Fosfatester (enligt CETOP RP 77H)                     HFD-R
  3 Säkra motorn.
  4 Skruva loss skruvarna med brickor som fäster motor-               Material
    fästet i fläkthuset. Se Bild 8.                                   Kylelement                                        Aluminium
  5 Skruva loss skruven med bricka som fäster fläkten med             Fläktblad/nav               Glasfiberförstärkt polypropylen/
    nav i motoraxeln. Se Bild 9. Dra försiktigt loss fläkten                                                            Aluminium
    med nav från motoraxeln. Använd avdragare vid behov.              Fläkthus                                                 Stål
  6 Skruva loss skruvarna som fäster motorn i motorfästet.            Fläktgaller                                              Stål
    Se Bild 11.                                                       Övriga delar                                             Stål
  7 Lyft bort motorn.                                                 Ytbehandling                   Elektrostatisk pulverlackering

  Vid ytterligare demontering av fläkten, märk upp alla delarna       Hydraulmotor
för att säkerställa korrekt återmontering, framförallt med            Maximalt arbetstryck                                210 bar
avseende på balans och rotationsriktning.                             (motor med depl. 25,2= 160 bar).
Se Bild 12.                                                           Rekommenderad olja              Mineralbaserad hydraulolja
                                                                                                     enligt DIN 51524 del 2 HLP
  Montering av hydraulmotor och fläkt                                 Rekommenderad oljeviskositet         20-50 cSt Min. 10 cSt
                                                                      Max. oljeviskositet vid drift                     100 cSt
  Anm! Vissa modeller har fast nav, se Bild 9, andra model-           Max. oljeviskositet vid kallstart                1000 cSt
ler har löst nav, se Bild 10 A och Bild 10 B. Fläkten hos             Rekommenderad oljetemperatur         30 - 60 °C Max 80 °C
modell LHC-033 och större är balanserad tillsammans med               Rekommenderad reningsnivå 18/13 eller högre
navet vid leverans.                                                   enligt ISO 4406.

  1 Skruva fast motorn i motorfästet. Se Bild 11.
  2 Passa in spåret i navet mot krysskilen på motorn.
    Använd etanol i navet som smörjning och tryck fast
    fläkten med nav på motoraxeln. Knacka eventuellt för-
    siktigt med t.ex. en gummiklubba. Applicera Loctite®
    på skruven och skruva fast fläkten med navet i motor-
    axeln. Se Bild 9.
3   Kontrollera att fläkten sitter fast på motoraxeln och
    inte glappar.
4   Lyft motorfästet med fläkten, fläktgallret och motorn
    på plats för montering i fläkthuset.
5   Justera in fläktgallret och motorn och skruva fast

The Professional Choice
OLAER/OA-Technik LHC AIR OIL COOLER | Installation and servicing manual | English                                               7

Introduction
This manual is meant to serve as a reference guide for             Overall instructions
instal-lation, maintenance and operation of the OLAER/
OA-Technik LHC-series of air oil cooler.                             Lifting
  Keep the manual at hand. A lost manual should be replaced
as soon as possible.
  For optimum performance and in order to prevent incorrect

                                                                   
use, please read this manual carefully and observe all safety
                                                                         Caution Risk of bodily injury. To prevent bodily harm
precautions prior to putting the air oil cooler into service.
                                                                         when lifting the unit, ensure correct lifting technique.
  Installation and maintenance work should be carried out by
                                                                   Make sure that all lifting devices are free from damage and
qualified personnel only.
                                                                   approved for the weight of the air oil cooler.
  OLAER/OA-Technik reserve the right to make technical
alternations without notice.
                                                                   Installation, operation, handling and maintenance
  Use The OLAER/OA-Technik LHC-series of air oil coolers
is designed to cool hydraulic fluids in systems for industrial
and mobile applications.
  Warranty and claims In the event of breakdown, consult
                                                                         Caution Risk of bodily injury. Disconnect the motor
                                                                          power supply prior to maintenance.
    your local OLAER/OA-Technik office. OLAER/OA-
 Technik shall not be held responsible for any consequences
          due to modification made by the customer.
                                                                        Caution Risk of bodily injury. Before disconnecting
                                                                         the hydraulic hoses and connections, make sure the
                                                                   system is depressurized.
Safety instructions
The installation contractor as well as the user should be aware
of, understand and observe all safety precautions in this
                                                                         Caution Risk of severe burns. This indicates danger
                                                                          from high temperature surfaces. The air oil cooler
manual, including any information mentioned on labels fixed        could become extremely hot during operation. Always make
to the product.                                                    sure the cooler is cool before touching.

  Definition of Safety Warning Levels…                                   Precaution Risk of bodily injury. If the air oil cooler
                                                                          is fitted with a thermo contact, the fan will start
                                                                   automatically when the preset temperature has been reached.
  …concerning personal safety                                      Be careful when standing close to rotating units.
All precautions concerning personal safety are classified as
per below, depending on how severe the consequences of an
incident could be.                                                        Precaution This indicates a toxic hazard. To prevent
                                                                           bodily injury, damage to property or environment, used
                                                                   fluid should be collected and taken to a special depôt.


       Danger This alerts you to an action or procedure that, if
       performed improperly, will produce bodily harm or death.      Important Risk of damage to the hydraulic system.
                                                                   Contamination, water and air will increase wear on hydraulic


      Caution This alerts you to an action or procedure that,      components, which could lead to breakdown. The most
      if performed improperly, is likely to produce bodily         important practice to observe when working on the hydraulic
harm or death.                                                     system is cleanliness.


       Precaution This alerts you to an action or procedure           Important Static electricity. Fans generate static electric-
       that, if performed improperly, is likely to cause an        ity. Do not put sensitive devices (electronics etc.) in the
accident with bodily harm.                                         immediate vicinity of the air oil cooler. Antistatic fans are
                                                                   available on request.
  ...concerning other safety issues
Notifications concerning other safety issues (property, process      Note! Use ear defenders when standing close to an oper-
or environment) and maintenance work are classified as fol-        ating air oil cooler for long periods of time.
lows:

  Important This alerts you to an action orprocedure that, if      Warning label
performed improperly, is likely to result in damage to the pro-
duct, process or environment.
                                                                   The warning label shown below is fitted to the oil cooler prior
                                                                   to delivery. Always replace a damaged or missing label.
  …concerning additional information                                 • Caution! High temperature surface! Use ear defenders!
Additional information is marked as follows:                            Rotating fan! (P/N 500029 - 70x30 mm or P/N 5000291
  Note! This alerts you to important information related to             - 120x50 mm). See Figure 1.
the text in a paragraph.

The Professional Choice
8                        OLAER/OA-Technik LHC AIR OIL COOLER | Installation and servicing manual | English

                                                                    the air oil cooler to allow for good air flow, i.e. optimal
Description                                                         cooling capacity as well as low acoustic pressure level. See
Principally the LHC air oil cooler consists of a cooler matrix,     Figure 3.
a hydraulic motor, a fan, a fan housing and a fan guard.              Inappropriate location of the air oil cooler or operation
  The cooler matrix and the hydraulic motor are connected           under extreme conditions could generate increased acoustic
to the hydraulic system with hydraulic hoses.                       pressure level and reduce cooling capacity.
  Different hydraulic motor types are used in the LHC series
of air oil coolers. Normal ambient temperature for the                Important Assembly and hydraulic motor installation
hydraulic motor is -20 °C – 60 °C.                                  should be made in a clean environment.
  For general technical information, see Technical data.
  Larger coolers are fitted with a collar bearing for prolon-
ged hydraulic motor life.
  If the air oil cooler is fitted with a thermo contact for         Connection of the cooler matrix
temperature sensing, the fan will start automatically when          Connect the cooler matrix using flexible hydraulic hoses
the preset temperature has been reached.                            both to and from the cooler matrix. Connections and hoses
  The acoustic pressure could reach 64-92 LpA dB(A) at 1 m          should be sized according to the system pressure, flow, tem-
distance under normal operating conditions depending on             perature and type of system fluid.
air oil cooler size. Inappropriate location of the air oil cooler   Connect the cooler matrix as illustrated below. See Figure 4.
could generate increased acoustic pressure level and reduced
cooling capacity to allow for good air flow, i.e. optimal cool-       A-   Inlet.
ing capacity.                                                         B-   Outlet for single pass
                                                                      C-   Outlet for two pass
                                                                      D-   Thermo contact connection.
Identification plate
                                                                      Dimensions on connections are cooler matrix size
The cooler identification plate is fitted on the fan housing.       dependent.
See Figure 2. On the label you will find information about            Connection chart, see Figure 5.

    A-   Part number                                                  Important The cooler matrix is designed for maximum dyna-
                                                                    mic working pressure 14 bar. When the cooler is installed in a
    B-   Designation
                                                                    return line, there should be no pressure spikes. If this is not
    C-   Serial number                                              possible, an offline cooling system should be used.
    D-   Date of delivery (year and week, e.g. 1018,
         i.e. year 2010 and week 18.

    Replace a damaged or missing label as soon as possible.         Connection of the hydraulic motor

                                                                      Important Risk of damage to the hydraulic system.
Installation                                                        Contamination, water and air will increase wear on hydraul-
                                                                    ic components, which could lead to breakdown. The most
    Lifting                                                         important practice to observe when working on the hydraul-
                                                                    ic system is cleanliness.

      Caution Risk of bodily injury. To prevent bodily harm
       when lifting the unit, ensure correct lifting tech-             Use flexible hydraulic hoses both to and from the hydrau-
                                                                    lic motor. Connections and hoses should be sized according
nique. Make sure that all lifting devices are free from dama-
ge and approved for the weight of the air oil cooler.               to system pressure, flow, temperature and type of system
                                                                    fluid. Prevent throttling and do not use flexible hydraulic
  Air oil coolers as from size 033 are prepared for                 hoses with a narrow bending radius.
installation of lifting eyes. Lifting eyes are available from          Connection size depends on hydraulic motor size.
OLAER/OA-Technik on request.                                           Adjust the oil flow to the hydraulic motor. The maximum
                                                                    rpm of the motor and fan must not be exceeded as this can
    Mounting                                                        cause a breakdown.

        Precaution Risk of bodily harm. Make sure that the
         air oil cooler is securely fixed.
                                                                       Be careful, incorrect connection will cause incorrect direc-
                                                                    tion of rotation of the motor and fan see arrow for direction
                                                                    of rotation.
  The air oil cooler can be mounted in any position.                   The LHC air oil cooler is fitted with an externally drained
However, upright is recommended (standing on its feet).             hydraulic motor as standard. Connect the hydraulic motor
A free space corresponding to a minimum of half the height          drain hose to the tank. Maximum pressure in drain port is 5 bar.
of the matrix (A) should be available in front of and behind
OLAER/OA-Technik LHC AIR OIL COOLER | Installation and servicing manual | English                                             9

                                                                During operation
Electrical connection
                                                                
                                                                       Caution Risk of severe burns. The air oil cooler could
If the cooler is fitted with a thermo contact, use a relay if          become extremely hot during operation. Make sure
the current load exceeds the maximum load for the thermo        that the air oil cooler is cool before touching.
contact.
                                                                   Maximum permitted fluid temperature in the cooler matrix
                                                                is 120° C. See Technical data for recommended fluid tempera-
Handling                                                        ture in the hydraulic motor.
                                                                   The cooler matrix is designed for maximum allowed dynamic
  Prior to initial start-up                                     working pressure 14 bar.
                                                                   Do not operate the hydraulic motor at a low rpm and a

      Precaution Make sure the air oil cooler is securely
       fixed and correctly connected.
                                                                high pressure for a long period of time.

                                                                  Note! Use ear defenders when standing in the immediate
  Be sure to use the correct fluid in the hydraulic motor as    vicinity of an operating air oil cooler for long periods of time.
well as a high-quality filter element to achieve a high level
of cleanliness. Make sure the hydraulic hoses and the tank
are clean.                                                      Preventive maintenance
                                                                Preventive maintenance work must be carried out at regular
We recommend that you proceed as follows prior to start-up:     intervals.
  1 Run the air oil cooler with the system fluid.
  2 Filter the fluid before passing through the cooler.           Important Risk of damage to the hydraulic system. Contami-
See Technical data for fluid compatibility, recommended         nation, water and air will increase wear on components, which
cleanliness level.                                              could lead to breakdown. The most important practice to
                                                                observe when working on the system is cleanliness.
  Prior to start up
                                                                  Make sure:

      Precaution Do not start the air oil cooler if there is
       a risk of damage to person, property or environment.
                                                                  • that there is no abnormal noise or vibrations,
                                                                  • that the air oil cooler is securely fixed,
                                                                  • that the cooler matrix is clean as debris will reduce the
  Check:                                                            cooling capacity,
  • that all cooler parts are free from damage,                   • that the fluid cleanliness is as recommended,
  • that the air oil cooler is correctly connected                  replace if required,
  • that the fan rotates freely (use hand force),                 • that the air oil cooler is free from damage, replace
  • that all hydraulic connections are tight,                       damaged components,
  • that the inside of the fan housing is free from objects       • that the air oil cooler is free from leaks, take
     that could be thrown around and cause bodily injury or         appropriate measures,
     damage to property.                                          • that warning labels are in good condition, replace any
                                                                    damaged/missing label immediately.
  At start-up
  Check:
  • that the direction of rotation of the fan and the air
                                                                Cleaning
     flow is as indicated by the arrows on the label on the

                                                                
     fan housing,                                                      Caution Risk of bodily injury. Prior to cleaning,
  • that the air oil cooler is free from abnormal noise and            disconnect all motor power supplies.
     vibrations,

                                                                
  • the air oil cooler is free from leaks, take adequate               Caution Risk of severe burns. The air oil cooler could
     measures                                                          become extremely hot during operation. Make sure
                                                                the air oil cooler is cool before touching.
  Consult OLAER/OA-Technik when using viscosity oil >
100 cSt (e.g. thick lubricating oils).                            Air oil cooler When cleaning the exterior of the cooler, for
                                                                instance using water, disconnect all power supplies.
  In order to protect the cooler matrix, use a by-pass valve      Cooler matrix The air fins of the matrix can be cleaned by
when operating in cold start mode/with thick lubricating        blowing through with compressed air. If necessary a high-
oils. See LHC brochure.                                         pressure washing system and degreasing agent can be used.
                                                                   When using a high-pressure washing system point the jet
                                                                parallel to the air fins. See Figure 6.

The Professional Choice
10                           OLAER/OA-Technik LHC AIR OIL COOLER | Installation and servicing manual | English

  Fan housing Remove the cooler matrix when cleaning the          3 Secure the hydraulic motor.
inside of the fan housing. To clean the inside of the fan         4 Unscrew the screws with washer fixing the motor
housing, use compressed air. Blow with compressed air from          attachment to the fan housing. See Figure 8.
the hydraulic motor side through the fan guard.                   5 Unscrew the screw with washer fixing the fan to the
                                                                    motor shaft. See Figure 9. Pull with care the fan and
                                                                    hub from the motor shaft. Use a puller if required.
Maintenance                                                       6 Unscrew the screws fixing the motor to the motor
OLAER/OA-Technik shall not be held responsible for any              attachment. See Figure 11.
consequences due to repair and/or modification made by            7 Remove the motor.
the customer.
  Dismounting the cooler matrix                                      If further dismounting of the fan is required, label all
                                                                     details to ensure correct mounting, first of all with

      Caution Risk of severe burns. The air oil cooler could        regard to balance and direction of rotation.
       become extremely hot during operation. Make sure              See Figure 12.
the air oil cooler is cool before touching.
                                                                  Mounting of the hydraulic motor and fan


       Caution Risk of bodily injury. Disconnect the motor
       power supply prior to maintenance.                         Note! There are models with fixed hub (see Figure 9) and
                                                                models with detachable hub (see Figure 10 A and Figure 10 B).
  1 Turn off the system.                                        The fan is balanced together with the hub as from size LHC-033.
  2 Disconnect the hydraulic motor power supply.
  3 Make sure that the system is depressurized.                   1 Secure the hydraulic motor to the motor attachment.
  4.Disconnect the oil inlets and outlets                           See Figure 11.
  5 Disconnect the flexible hydraulic hoses from the cooler       2 Fit the hub groove to the motor spline. Lube the hub
    matrix.                                                         with ethanol and secure the fan/hub to the motor
  6 Unscrew the screws with washers fixing the cooler               shaft. If required, knock carefully with e.g. a rubber
    matrix to the fan housing. See Figure 7.                        mallet. Use Loctite® on the screw and secure the
  7 Remove the cooler matrix.                                       fan/hub on the motor shaft with screws. See Figure 9.
                                                                  3 Make sure that the fan is fitted to the motor shaft
  Mounting of the cooler matrix                                     without too much play.
  1 Locate the cooler matrix.                                     4 Place the motor attachment with fan, fan guard and
  2 Fit the cooler matrix to the fan housing. See Figure 7.         motor in the fan housing.
  3 Connect the flexible hydraulic hoses to the cooler            5 Adjust the fan guard and motor and secure the motor
    matrix. See Figure 4.                                           attachment in the fan housing with screws.
  4 Connect the hydraulic motor power supply.                       See Figure 8.
  5 Proceed to Prior to start-up and At start-up                  6 Make sure that the fan is centered and rotates freely
                                                                    (using hand force). If required, adjust the location of
  Removing the hydraulic motor and the fan                          the fan guard and motor.
                                                                  7 Check the screws for tightness.
                                                                  8 Connect the hydraulic motor power supply.

       Caution Risk of severe burns. The air oil cooler could
                                                                  9 Proceed to Prior to start-up and At start-up.
       become extremely hot during operation. Make sure
the air oil cooler is cool before touching.


       Caution Risk of bodily injury. Prior to maintenance,
       disconnect the hydraulic motor power supply.

   Important Risk of damage to the hydraulic system.
Contamination, water and air will increase wear on hydrau-
lic components, which could lead to breakdown. The most
important practice to observe when working on the hydrau-
lic system is cleanliness.

  Note! Some fan hubs are fixed, see Figure 9, and some are
detachable, see Figure 10 A and Figure 10 B. The fan is
balanced together with the hub as from size LHC-033.

  1 Turn off the system.
  2 Disconnect the hydraulic motor power supply.
OLAER/OA-Technik LHC AIR OIL COOLER | Installation and servicing manual | English   11

Technical data
 Cooler matrix
 Maximum static working pressure                 21 bar
 Maximum dynamic working pressure               14 bar*
 Heat transfer allowance                          ± 6%
 Maximum fluid temperature in the cooler matrix 120 °C
 Maximum cooling capacity                       160 kW
 * Tested according to ISO/DIS 10771-1

 Fluid compatibility
 Mineral oil according to DIN 51524                    HL/HLP
 Oil/water emulsion according to CETOP RP 77H         HFA, HFB
 Water glycol according to CETOP RP 77H                    HFC
 Phosfatester according to CETOP RP 77H                  HFD-R

 Hydraulic motor
 Maximum working pressure                               210 bar
 (motor with depl. 25.2 = 160 bar)
 Recommended fluid type              Mineral based hydraulic oil
 according to DIN 51524 part 2HLP
 Recommended oil viscosity     20 - 50 cSt. Min. 10 cSt
 Max. operating viscosity                      100 cSt
 Max. viscosity at cold start                 1000 cSt
 Recommended fluid temperature 30 – 60 °C. Max. 80 °C
 Recommended cleaning level 18/13 or higher
 according to ISO 4406

 Material
 Cooler matrix                                Aluminium
 Fan housing                                        Steel
 Fan blades/hub    Glass fibre reinforced polypropylene/
                                              aluminium
 Fan guard                                          Steel
 Other parts                                        Steel
 Hydraulic motor See information from the manufacturer
 Surface treatment           Electrostatic powder coated

OLAER/OA-Technik LHC air oil coolers could have
different material and surface treatments.

The Professional Choice
OLAER/OA-Technik LHC AIR OIL COOLER | Installation and servicing manual                  | Deutsch                         13

                                                                    ...und Zusatzangaben
Einleitung                                                        Die Zusatzangaben werden wie folgt gekennzeichnet:
Diese Anleitung bezieht sich auf die OLAER/OA-Technik
LHC-Baureihe von Öl/Luftkühlern. Sie soll als Hilfsmittel bei       Hinweis! Bezieht sich auf Zusatzinformationen, die das
Installation, Einsatz und Wartung des Öl/Luftkühlers dienen.      Verständnis fur einen bestimmten Teilbereich oder den Um-
  Diese Anweisung ist so zu verwahren,dass sie jederzeit ver-     gang damit erleichtern.
fügbar ist. Wenn sie verloren geht, ist sie sofort zu ersetzen.
  Anweisungen und Warntexte sind sorgfältig zu lesen und
entsprechend zu beachten, bevor der Öl/Luftkühler zum             Übergeordnete Vorschriften
Einsatz kommt. Damit wird sichergestellt, dass der Öl/Luft-
kühler optimal genutzt und eine fehlerhafte Benutzung aus-
geschlossen wird.
                                                                    Anheben
  Zu diesem Zweck darf nur geschultes Personal den Öl/Luft-

                                                                  
kühler installieren, bedienen und warten.
OLAER/OA-Technik behält sich technische Änderungen                       Warnung Quetschgefahr. Damit beim Anheben Verletz-
vor.                                                                     ungen verhindert werden, ist das richtige Hebever-
                                                                  fahren anzuwenden. Sicherstellen, dass die verwendeten
  Einsatzbereiche Der OLAER/OA-Technik LHC Öl/Luft-               Hebevorrichtungen und -geräte keine Fehler aufweisen und
  kühler ist für die Kühlung von Hydraulikflüssigkeit in          für das Gewicht des Öl/Luftkühlers zugelassen sind.
Systemen für industrielle und mobile Anlagen vorgesehen.
  Garantie und Reklamationen Im Störungsfall, wenden                Installation, Betrieb, Bedienung und Wartung
Sie sich bitte an Ihren OLAER/OA-Technik Partner.
OLAER/OA-Technik haftet nicht für Folgeschäden, die
durch eigenmächtige Reparaturen und/oder Veränderungen
durch den Kunden entstehen.
                                                                       Warnung Verletzungsgefahr! - Vor Wartungsarbeiten
                                                                        den Motorantrieb abschalten und entsprechend vom
                                                                  Stromnetz absperren.
Sicherheitsvorschriften
Installateure und Anwender müssen Warnungen und
Hinweise auf Schildern, Aufklebern, sowie diese Anweis-
                                                                       Warnung Verletzungsgefahr! - Vor dem Lösen von
                                                                        Hydraulikanschlüssen sicherstellen, dass kein Druck
                                                                  mehr in der Anlage vorhanden ist.
ungen lesen und beachten.

  Warnstufen und Hinweistexte                                            Warnung Ernsthafte Verbrennungsgefahr! - Im Betrieb
                                                                          kann der Öl/Luftkühler sehr heiß werden. Daher sollte
                                                                  er erst berührt werden, wenn er sich abgekühlt hat.
  ...zur persönlicher Sicherheit
Hinweistexte zur persönlichen Sicherheit sind in die drei
nachstehend beschriebenen Stufen unterteilt, die sich an                Vorsicht Quetschgefahr! - Der Öl/Luftkühler kann
                                                                         sich über einen Thermokontakt regeln. Das Lüfterrad
den möglichen ernsthaften Folgen eines Unfalls orientieren.       läuft dann bei Erreichen der Einschalttemperatur auto-
                                                                  matisch an. In der Nähe sich drehender Komponenten

      Gefahr weist darauf hin, dass ein Unfall sich ereignen     äußerst vorsichtig vorgehen.
       wird, wenn diese Vorschriften nicht beachtet werden.
Ein solcher Unfall führt zu ernsthaften Verletzungen oder
sogar zu Todesfällen.                                                   Vorsicht Vergiftungsgefahr! - Verbrauchtes Öl ist in
                                                                         der dafür vorgesehenen Entsorgungsanlage zu ent-
                                                                  sorgen, damit es nicht zu Verletzungen oder Schäden an

      Warnung weist darauf hin, dass ein Unfall sich ereignen    Gegenständen oder der Umwelt kommt.
       kann, wenn diese Vorschriften nicht beachtet werden.
Ein solcher Unfall kann zu ernsthaften Verletzungen oder            Wichtig Beschädigungsgefahr des Hydrauliksystems!
sogar zu Todesfällen führen.                                      Verschmutzung, Wasser und Luft verursachen Verschleiß der
                                                                  Hydraulikkomponenten, was zu einem Stillstand des


       Vorsicht weist darauf hin, dass ein Unfall sich ereignen   Hydrauliksystems führen kann. Bei Arbeiten am Hydraulik-
       kann, wenn diese Vorschriften nicht beachtet werden.       system muss auf hohe Sauberkeit geachtet werden.
Ein solcher Unfall kann zu Verletzungen führen.
                                                                    Wichtig Statische Elektrizität! - Der Lüfter kann statische
  ...und sonstigen Sicherheit                                     Ladung durch Luftreibung erzeugen. Bringen Sie keine emp-
  Hinweistexte zur sonstigen Sicherheit (Gegenstände, Prozesse    findlichen Geräte (Elektronik usw.) in die unmittelbare Nähe
oder Umfeld) und Bedienung sind wie folgt unterteilt.             des Öl/Luftkühlers. Antistatisches Lüfterrad kann separat
                                                                  bestellt werden.
  Wichtig weist darauf hin, dass ein Unfall sich ereignen
kann, wenn diese Vorschriften nicht beachtet werden. Ein            Hinweis! Beim längerem Aufenthalt in der Nähe des Öl/-
solcher Unfall kann zu Beschädigungen an Gegenständen,            Luftkühlers im Betrieb ist ein Gehörschutz zu tragen.
Prozessen und Umfeld führen.
14                        OLAER/OA-Technik LHC AIR OIL COOLER | Installation and servicing manual | Deutsch

Warnaufkleber
                                                                Montage
Der nachstehend definierte Aufkleber ist bei Lieferung am
Öl/Luftkühler angebracht. Ein beschädigter oder fehlender
Aufkleber ist sofort zu ersetzen.                                     Vorsicht Verletzungsgefahr! Sicherstellen, dass der
                                                                       Öl/Luftkühler immer ausreichend gesichert ist.
  • Warnung! Heiße Oberflächen! Gehörschutz tragen!
     Rotierendes Lüfterrad! (Art.-Nr. 500029 – 70 x 30 mm       Der Öl/Luftkuhler kann in jeder Position montiert werden,
     oder Art.-Nr. 5000291 – 120 x 50 mm) Siehe Abb. 1.         die stehende Anbringung auf den Füßen ist jedoch zu bevor-
                                                                zugen. Der Abstand zur nächstliegenden Wand hinter und vor
                                                                dem Kühler sollte die halbe Höhe des Kühlelements (A) nicht
                                                                unterschreiten, damit eine optimale Kühlleistung durch gute
Beschreibung                                                    Luftversorgung und ein geringer Schalldruckpegel erzielt
Der LHC Öl/Luftkühler besteht im Wesentlichen aus einem         werden. Siehe Abb. 3. Eine unvorteilhafte Anbringung oder
Hydraulikmotor, einem Kühlelement, einem Lüfterrad, einem       Betrieb unter extremen Betriebsbedingungen, kann einen
Lüftergehäuse und einem Schutzgitter.                           hohen Schalldruckpegel und eine verringerte Kühlleistung
  Das Kühlelement und der Hydraulikmotor werden über            verursachen.
Hydraulikschläuche an die Hydraulikanlage angeschlossen.
In die LHC-Baureihe werden verschiedene Hydraulikmotoren          Hinweis! Installation und Montage des Hydraulikmotors
eingebaut. Normale Umgebungstemperatur des Hydraulik-           immer in sauberer Umgebung durchführen.
motors: -20 °C - 60 °C.
  Für spezifische Betriebsdaten, siehe Technische Daten.        Anschluss des Kühlelements
Große Kühler sind für eine lange Lebensdauer des
Hydraulikmotors mit Vorsatzlager ausgerüstet.                   Benutzen Sie Hydraulikschläuche auf der Ein- und Austritts-
  Ist der Öl/Luftkühler mit einem Thermokontakt für             seite des Kühlelements. Sicherstellen, dass alle Anschlüsse
Temperaturregelung Ausgestattet, läuft das Lüfterrad bei        und Schläuche an Druck, Ölvolumenstrom, Temperatur und
Erreichen der Einschalttemperatur automatisch an.               Fluüssigkeit der Anlage angepasst sind.
  Im Normalbetrieb beträgt der maximale Schalldruckpegel        Hydraulikschläuche wie folgt an das Kühlelement anschließen:
im Abstand von 1 m zwischen 62 und 93 LpA dB(A), je nach        Siehe Abb. 4.
Größe des Öl/Luftkühlers. Wenn der Kühler unsachgemäss ang-       A - Eintritt.
ebracht wurde, kann der Schalldruckpegel über angegebenen         B - Austritt für Einzeldurchlauf.
Wert ansteigen und eine verringerte Kühlleistung verursachen.     C - Austritt für Doppeldurchlauf.
                                                                  D - Anschluss fur Thermokontakt

Typenschild                                                       Die Anschlussdurchmesser sind abhängig von der Größe
                                                                des Kühlelements.
Das Typenschild des Öl/Luftkühlers befindet sich am Lüfter-       Schaltplan: siehe Abb. 5.
gehäuse. Siehe Abb. 2.
Das Typenschild enthält Angaben zu:                                Wichtig Das Kuhlelement ist auf einen maximalen dynami-
  A - Artikelnummer                                             schen Betriebsdruck von 14 bar ausgelegt. Druckstöße sind
  B - Artikelbezeichnung                                        bei der Installation des Öl/Luftkühlers in der Rucklaufleitung
  C - Seriennummer                                              des Systems zu meiden. Falls dies nicht möglich ist, instal-
  D - Lieferdatum (Jahr und Kalenderwoche, z. B. 1018,          lieren Sie den Kühler in einen getrennten Kreislauf.
       also Jahr 2010 und KW 18.)

  Ein beschädigtes oder fehlendes Typenschild ist sofort zu     Anschluss des Hydraulikmotors
ersetzen.

Installation                                                      Wichtig Beschädigungsgefahr des Hydrauliksystems!
Anheben                                                         Verschmutzung, Wasser und Luft verursachen Verschleiß der
                                                                Hydraulikkomponenten, was zu einem Stillstand des

      Warnung Quetschgefahr! Damit beim Anheben Verletz-
       ungen vermieden werden, ist das richtige Hebever-
                                                                Hydrauliksystems führen kann. Bei Arbeiten am Hydraulik-
                                                                system muss auf hohe Sauberkeit geachtet werden.
fahren zu verwenden. Sicherstellen, dass die verwendeten
Hebevorrichtungen und -geräte keine Fehler aufweisen und für      Zum und vom Hydraulikmotor sind Hydraulikschläuche zu
das Gewicht des Öl/Luftkühlers zugelassen sind.                 verwenden. Dabei ist sicherzustellen, dass alle Anschlüsse
                                                                und Schläuche an Druck, Ölvolumenstrom, Temperatur und
  Alle Öl/Luftkühler ab Größe 033 sind für Hebeösen             Flüssigkeit angepasst werden.
vorberei-tet. Hebeösen sind als Zubehör von OLAER/OA-
Technik zu bestellen.
OLAER/OA-Technik LHC AIR OIL COOLER | Installation and servicing manual | Deutsch                                             15

  Drosseln sind zu vermeiden wie auch Rohrbogen mit                  Beim Start
engem Radius.
  Die Anschlussdurchmesser sind abhängig von der Größe             Überprufen Sie:
des Hydraulikmotors.                                                • die richtige Drehrichtung des Lufterrads, sowie die
  Beim Anschluss des Hydraulikmotors darf die angegebene               Übereinstimmung des Luftdurchsatzes mit den Angaben
Drehzahl des Motors oder des Lüfters nicht überschritten               auf dem Aufkleber am Luftergehäuse,
werden. Der Betrieb mit zu hoher Drehzahl kann zu                   • dass keine ungewöhnlichen Geräusche oder Vibrationen
Beschädigungen des Motors oder des Lüfters führen.                     vorkommen,
  Beim Anschluss ist sehr vorsichtig zu arbeiten! Falsche           • dass keine Leckage vorhanden ist.
Anschlüsse, können dazu führen, dass sich der Motor in die
falsche Richtung dreht.                                            Wenden Sie sich bitte an OLAER/OA-Technik beim
  Der OLAER/OA-Technik LHC Öl/Luftkühler ist                       Einsatz von Öl mit Viskosität > 100 cSt (z. B. dickflüssiger
standardmäßig mit einem Hydraulikmotor mit externem                Schmieröle).
Ablass ausgerüstet. Der Ablassschlauch ist direkt am Tank          Um das Kühlelement zu schützen, ist ein Bypassventil bei
anzuschließen. Maximaler Druck im Ablassanschluss ist 5            Kaltstartbedingungen/dickflüssiger Schmieröle anzuschlies-
bar.                                                               sen. Siehe LHC Brochure.
Elektrischer Anschluss
Ist der LHC Öl/Luftkühler mit einem Thermokontakt ausge-             Im Betrieb
stattet, sollte ein Relais verswendet werden falls die Stromlast
über dem für den Thermokontakt zulässigen Wert liegt.
                                                                   
                                                                           Warnung Ernsthafte Verbrennungsgefahr! Im Betrieb
                                                                           kann der Öl/Luftküühler sehr heiß werden. Daher soll-
Bedienung                                                          te er erst berührt werden, wenn er sich abgekuhlt hat.

Vor dem ersten Start                                                 Die maximal zulässige Öltemperatur im Kühlelement


        Vorsicht Verletzungsgefahr! Sicherstellen, dass der          beträgt 120 °C.
        Öl/Luftkühler immer ordnungsgemäß befestigt ist und          Die maximal zulässige Flüssigkeitstemperatur im Motor ist
richtig angeschlossen ist.                                         in Technische Daten beschrieben.
                                                                     Das Kühlelement ist auf einen maximalen dynamischen
  Um ein hohes Reinigungsniveau gewährleisten zu können,           Betriebsdruck von 14 Bar ausgelegt.
sind geeignete Flüssigkeiten wie auch entsprechende                  Betrieb vom Hydraulikmotor mit niedriger Drehzahl und
Qualitätsfilter im Hydraulikmotor zu verwenden.                    hohem Druck über eine lange Zeit ist zu vermeiden.
  Es ist sicherzustellen, dass alle Schläuche und der Tank
gereinigt sind.                                                      Hinweis! Beim längerem Aufenthalt in der Nähe des
                                                                   Öl/Luftkuhlers im Betrieb ist ein Gehörschutz zu tragen.
OLAER/OA-Technik empfiehlt folgende
Vorgehensweise vor der inbetriebnahme des Öl/
Luftkühlers:
1 Öl/Luftkühler mit derselben Flüssigkeit wie im
                                                                   Vorbeugende Wartung
sonstigen System durchspülen.                                      Die wichtigsten Wartungsmaßnahmen dienen der Vorbeugung
                                                                   und sind vom Anwender in regelmäßigen Abständen durch-
2 Die Flüssigkeit vor dem Durchlauf des Kühlers filtern.           zuführen.

  Die empfohlenen Flüssigkeitskombinationen und Reini-               Wichtig Beschädigungsgefahr des Hydrauliksystems! Ve r -
gungsniveau, sind in, Technische Daten angegeben.                  schmutzung, Wasser und Luft verursachen Verschleiß der
                                                                   Hydraulikkomponenten, was zu einem Stillstand des Hydraulik-
  Vor dem Start                                                    systems fuhren kann. Bei Arbeiten am Hydrauliksystem muss
                                                                   auf hohe Sauberkeit geachtet werden.


       Vorsicht Der Öl/Luftkühler nicht in Betrieb nehmen,
       wenn Gefahr von Schäden und Verletzungen an                   Überprüfen Sie:
Personen, Material oder Umwelt hoch ist.                             • dass keine ungewöhnlichen Geräusche oder Vibrationen
Überprufen Sie:                                                        vorkommen,
  • alle Teile des Öl/Luftkühlers auf Beschädigungen,                • dass der Öl/Luftkühler ausreichend gesichert ist,
  • dass der Öl/Luftkühler richtig angeschlossen ist,                • dass das Kühlelement sauber ist - Verunreinigungen
  • dass das Lüfterrad frei rotieren kann (mit der Hand                verschlechtern die Kühlleistung,
     bewegen),                                                       • das Reinheitsniveau - Flüssigkeit bei Bedarf wechseln.
  • dass alle hydraulischen Anschlüsse gut angezogen sind,           • dass der Öl/Luftkühler unbeschädigt ist - defekte Teile
  • dass die Innenseite des Lüftergehäuses frei von Gegen-             sind auszutauschen,
     ständen ist, die weggeschleudert werden und Personen            • dass keine Leckage vorhanden ist - eventuelle Leckage
     verletzen oder Dinge beschädigen können.                          ist zu beheben,
The Professional Choice
16                         OLAER/OA-Technik LHC AIR OIL COOLER | Installation and servicing manual | Deutsch

 • dass der Warnaufkleber sich in einem guten Zustand           3 Die Hydraulikschläuche am Kühlelement anschließen.
   befindet. Ist er beschädigt oder entfernt worden, ist er       Siehe Abb. 4.
   sofort zu ersetzen.                                          4 Den Motorantrieb einschalten.
                                                                5 Maßnahmen gemäß Anweisungen
                                                                  Vor dem Start und Beim Start durchführen.
Reinigung
                                                                Demontage von Hydraulikmotor und Lüfterrad

     Warnung Verletzungsgefahr! Vor der Reinigung den

                                                              
      Motorantrieb abschalten.                                        Warnung Ernsthafte Verbrennungsgefahr! Im Betrieb
                                                                      kann der Öl/Luftkühler sehr heiß werden. Daher sollte

      Warnung Ernsthafte Verbrennungsgefahr! Im Betrieb
       kann der Öl/Luftkühler sehr heiß werden. Kühlelement
                                                              er erst berührt werden, wenn er sich abgekühlt hat.

                                                              
vor der Reinigung abkühlen lassen.                                   Warnung Verletzungsgefahr! Vor Wartungsarbeiten
                                                                     den Motorantrieb abschalten.
  Öl/Luftkühler Bei äußeren Reinigungsarbeiten, z.B. mit
Wasser, trennen Sie den Kühler von der Stromversorgung.         Wichtig Beschädigungsgefahr des Hydrauliksystems!
  Kühlelement Die Luftlamellen können mit Druckluft gerei-    Verschmutzung, Wasser und Luft verursachen Verschleiß der
nigt werden. Wenn notwendig; Hochdruckwaschanlage und ein     Hydraulikkomponenten, was zu einem Stillstand des Hydraulik-
Entfettungsmittel verwenden. Beim Einsatz einer Hochdruck-    systems führen kann. Bei Arbeiten am Hydrauliksystem muss
waschanlage muss der Strahl vorsichtig parallel zu den        auf hohe Sauberkeit geachtet werden.
Luftlamellen gehalten werden. Siehe Abb. 6.
  Lüftergehäuse Das Kühlelement zur Innenreinigung des          Hinweis! Einige Modelle haben eine starre Nabe. Siehe
Lüftergehäuses abnehmen. Das Innere des Lüftergehäuses        Abb. 9. Andere Modelle haben eine lose Nabe. Siehe Abb. 10 A
wird nur mit Druckluft gereinigt. Bei Bedarf kann ein         und Abb. 10 B. Das Lüfterrad ist bei der Lieferung ab der
Entfetter eingesetzt werden. Die Druckluft von der            Größe LHC-033 mit der Nabe ausgewuchtet.
Hydraulikmotorseite durch das Schutzgitter einleiten.
                                                                1 Anlage abschalten.
                                                                2 Den Motorantrieb abschalten.
                                                                3 Den Motor sichern.
Wartung                                                         4 Die Schrauben samt Unterlegscheiben abschrauben, mit
OLAER/OA-Technik haftet nicht für Folgeschäden, die               denen die Motorhalterung am Lüftergehäuse befestigt
durch Reparatur und/oder Modifikation bei der Anwender            ist. Siehe Abb. 8.
entstehen.                                                      5 Die Schraube samt Unterlegscheibe abschrauben, mit
 Demontage des Kühlelements                                       denen das Lüfterrad mit Nabe an der Motorwelle be-
                                                                  festigt ist. Siehe Abb. 9.
                                                                  Das Lüfterrad mit Nabe vorsichtig von der Motorwelle


       Warnung Ernsthafte Verbrennungsgefahr!
                                                                  abziehen. Bei Bedarf einen Abzieher verwenden.
       Im Betrieb kann der Öl/Luftkühler sehr heiß werden.
                                                                6 Die Schrauben abschrauben, mit denen der Motor an der
Daher sollte er erst beruhrt werden, wenn er sich abgekühlt
                                                                  Motorhalterung befestigt ist. Siehe Abb. 11.
hat.
                                                                7 Den Motor abnehmen.

     Warnung Verletzungsgefahr! Vor Wartungsarbeiten
      den Motorantrieb abschalten.
                                                                Bei einer weiteren Zerlegung des Lüfters sind alle Teile zur
                                                              Sicherstellung der korrekten Montage zu kennzeichnen, vor allen
                                                              Dingen unter den Aspekten Auswuchtung und Drehrichtung.
 1 Anlage abschalten.
                                                              Siehe Abb. 12.
 2 Den Motorantrieb abschalten.
 3 Sicherstellen, dass sich kein Druck mehr in der Anlage
                                                              Montage von Hydraulikmotor und Lüfterrad
   befindet.
 4 Öleintritt und -austritt abschalten.
                                                                Hinweis! Einige Modelle haben eine starre Nabe. Siehe
 5 Die Hydraulikschläuche vom Kühlelement abnehmen.
                                                              Abb. 9. Andere Modelle haben eine lose Nabe.
 6 Die Schrauben samt Unterlegscheiben abschrauben, mit
                                                              Siehe Abb. 10 A und Abb. 10 B. Das Lufterrad ist bei der
   denen das Kühlelement am Lüftergehäuse befestigt ist.
                                                              Lieferung ab der Größe LHC-033 mit der Nabe ausgewuchtet.
   Siehe Abb. 7.
                                                                1 Den Motor an der Motorhalterung anschrauben.
 7 Das Kühlelement abnehmen.
                                                                   Siehe Abb. 11.
                                                                2 Das Lüfterrad wird auf der Motorwelle derart montiert,
 Montage des Kühlelementes
                                                                   dass die in der Lüfterradnabe angebrachte Nut auf die
 1 Das Kühlelement anbringen.
                                                                   mit einer Passfeder versehene Motorwelle entsprechend
 2 Das Kühlelement am Lüftergehäuse anschrauben.
                                                                   justiert und aufgesetzt wird. Bei der Montage des
   Siehe Abb. 7.
Vous pouvez aussi lire