COOLING 4,0-196 kW HEATING 5,1-238 kW PRODUCT OVERVIEW LIQUID CHILLERS AND HEAT PUMPS WITH SCROLL COMPRESSORS REFRIGERATORI D’ACQUA E POMPE DI CALORE CON COMPRESSORI SCROLL ENFRIADORAS DE AGUA Y BOMBAS DE CALOR CON COMPRESORES SCROLL GROUPES D’EAU GLACÉE ET POMPES À CHALEUR AVEC COMPRESSEURS SCROLL G.I. INDUSTRIAL HOLDING S.p.A. participates in the ECC programme for LCP-HP, FCU and AHU. Check on-going validity of certificate: www.eurovent-certification.com or www.certiflash.com
2 LIQUID CHILLERS AND HEAT PUMPS WITH SCROLL COMPRESSORS VERSIONS / VERSIONI / VERSIONES / VERSIONS ErP SEER ErP SCOP
4 R452B: THE LOW GWP SUBSTITUTE FOR R410A -65% GWP 1924 676 GWP GWP SOLSTICE® L41Y & OPTEON™ XL55 (DR55) R410A R452B ENVIRONMENTALLY FRIENDLY GWP = 676 ODP = 0. SAFE AND HIGHLY PERFORMING A2L CLASS WIDE APPLICATION HEAT PUMPS LIQUID CHILLERS MULTIFUNCTIONAL UNITS ECOLOGICO ECOLÓGICO ÉCOLOGIQUE GWP = 676 GWP = 676 GWP = 676 ODP = 0. ODP = 0. ODP = 0. SICURO E PERFORMANTE SEGURO Y EFICIENTE SÛR ET PERFORMANT classe A2L clase A2L classe A2L AMPIA APPLICAZIONE AMPLIA APLICACIÓN LARGE APPLICATION Pompe di Calore Bombas de Calor Pompes à Chaleur Refrigeratori d’Acqua Enfriadoras de agua Groupes d’eau glacée Unità Polifunzionali Unidades Polifuncionales Unités Polyfonctionnelles GWP= Global Warming Potential Potenziale di Riscaldamento Globale Potencial de Calentamiento Atmosférico Potentiel de Réchauffement Planétaire ODP= Ozone Depletion Potential Potenziale di Degradazione dello strato di Ozono Potencial de Agotamiento del Ozono Potentiel d’Appauvrissement de la couche d’Ozone
5 R454B -31% GWP 676 467 GWP GWP OPTEON™ XL41 (DR5A) R452B R454B ENVIRONMENTALLY FRIENDLY GWP = 467 ODP = 0. SAFE AND HIGHLY PERFORMING A2L CLASS WIDE APPLICATION HEAT PUMPS LIQUID CHILLERS MULTIFUNCTIONAL UNITS ECOLOGICO ECOLÓGICO ÉCOLOGIQUE GWP = 467 GWP = 467 GWP = 467 ODP = 0. ODP = 0. ODP = 0. SICURO E PERFORMANTE SEGURO Y EFICIENTE SÛR ET PERFORMANT classe A2L clase A2L classe A2L AMPIA APPLICAZIONE AMPLIA APLICACIÓN LARGE APPLICATION Pompe di Calore Bombas de Calor Pompes à Chaleur Refrigeratori d’Acqua Enfriadoras de agua Groupes d’eau glacée Unità Polifunzionali Unidades Polifuncionales Unités Polyfonctionnelles GWP= Global Warming Potential Potenziale di Riscaldamento Globale Potencial de Calentamiento Atmosférico Potentiel de Réchauffement Planétaire ODP= Ozone Depletion Potential Potenziale di Degradazione dello strato di Ozono Potencial de Agotamiento del Ozono Potentiel d’Appauvrissement de la couche d’Ozone
6 COMPLIANCE WITH ErP DIRECTIVES ECODESIGN ECODESIGN The EUROPEAN UNION Regulations designed to precisely determine Direttive dell’UNIONE EUROPEA atte a definire con precisione the Minimum Energy Efficiency Standards for Electric i Minimi Standard di Efficienza Energetica per gli Electric related Products ErP. related Products ErP (Prodotti Elettrici correlati). Mandatory compliance for the following standards: Conformità obbligatoria per standard di: DIFFERENT REGULATIONS AND STANDARDS: DIVERSE DIRETTIVE E STANDARD: Heat pump units. Regulation n. 813/2013. Unità a pompa di calore. Direttiva n. 813/2013. Units are compliant with ErP Regulation by exceeding the minimum Cooling only units (comfort). Regulation n. 2016/2281. Unità per solo raffreddamento(comfort). Direttiva n. 2016/2281. Units are compliant with ErP Regulation by exceeding the A wide range of units is compliant with ErP 2021 standards. Un’ampia gamma di unità conforme ai requisiti ErP 2021. ErP SCOP ErP SEER 2021 ECODESIGN ECODESIGN Directivas de la UNION EUROPEA apto para definir con precisión los Réglementations de l’UNION EUROPÉENNE aptes à établir avec préci Mínimos Estándares de Eficiencia Energética para los Electric sion les Standards Minimales d’Efficacité Energétique pour les related Products ErP (Productos Eléctricos coreados). Electric related Products ErP (Produits Électriques corrélés). Conformidad obligatoria para estándares de: Conformité obligatoire pour standard de : DIFERENTES DIRECTIVAS Y ESTÁNDARES: DIFFÉRANTS RÉGLEMENTATIONS ET STANDARDS : Unidades de bomba de calor. Directiva n. 813/2013. Unités à pompe à chaleur. Réglementation n. 813/2013. Les unités sont conformes à la réglementation ErP en dépassant les exigences Unidades para solo frío (confort). Directiva n. 2016/2281. Unités pour froid seul (confort). Réglementation n. 2016/2281. Las unidades son conformes con la directiva ErP superando Les unités sont conformes à la réglementation ErP en dépassant Una amplia gama de unidades es conforme con los requisitos Une vaste gamme d’unités est conforme aux exigences ErP 2021. ErP 2021.
8 INVERTER SCROLL COMPRESSOR INVERTER SCROLL The SCROLL compressor is fully managed by an INVERTER VARIABLE FREQUENCY DRIVE that electronically modulates the compressor INVERTER VARIABLE FREQUENCY DRIVE che modula elettronicamente la VELOCITÀ del El compresor Scroll es enteramente gestionado por INVERTER VARIABLE FREQUENCY DRIVE INVERTER VARIABLE FREQUENCY DRIVE EFFICIENCY AT PART LOAD TOP SEER/SCOP: EFFICIENCY AT PART LOAD TOP SEER/SCOP: EFFICIENZA AI CARICHI PARZIALI TOP SEER/SCOP: EFFICIENCIA A CARGAS PARCIALES TOP SEER/SCOP: EFFICACITÉ À CHARGES PARTIELLES Les puissances utile et absorbée sont PROPORTIONNELLMENT modulées Puissance absorbée réduite avec fonctionnement à charges partielles SEER: SEASONAL ENERGY EFFICIENCY IN COOLING SCOP: SEASONAL ENERGY EFFICIENCY IN HEATING SEER SEER SCOP SCOP 4,30 4,30 3,70 3,70 4,20 4,20 3,60 3,60 4,10 4,10 3,50 3,50 ErP 2021 ErP 2021 4,00 4,00 12% Up to +Up to +12% Up to +11% Up to +11% 3,40 3,40 3,90 3,90 3,30 3,30 3,80 3,80 ErP 2018 ErP 2018 3,20 3,20 3,70 3,70 3,10 3,10 0 020 20 40 40 60 60 80 80 100 100 120 120 140 140 160 160 180 180 200 200 0 50 0 5550 6555 7565 8575 10085 110 100130 110150 130180 150210 180 210 CoolingCooling capacity capacity (kW) (kW) Inverter Inverter unit withunit Microchannel with Microchannel (CHA/IK/A/MC) (CHA/IK/A/MC) Inverter Inverter unit (CHA/IK/A) unit (CHA/IK/A) Inverter Inverter unit (CHA/IK/A) unit (CHA/IK/A) On/off unit On/off unit On/off unit On/off (CHA/K/AF) unit (CHA/K/AF) On/off unit On/off unit
9 INVERTER SCROLL COMPRESSOR AMPERAGE NO CURRENT PEAK AT START-UP I Compressor start DOL = Direct Online SOFT START device INVERTER NO PICCHI DI CORRENTE IN AVVIAMENTO Permette il ridimensionamento del sistema elettrico dell’edificio: risparmio sui costi fissi caricati dalle utenze TIME NO PICOS DE CORRIENTE EN LA PUESTA EN MARCHA Permite la reducción del sistema eléctrico del edificio: ahorro Reduce de cargas principales y respaldo de energía PAS PICS DE COURANT DANS LE DÉMARRAGE NO CURRENT PEAK du batîment: économies sur les coûts fixes facturés Il réduit des charges principales et des sauvegardes TEMPERATURE FLUCTUATIONS Water Stable temperature MORE COMFORT Time Set temperature CHA/IK/A Inverter CHA/K On-Off CONSTANT LEVEL OF WATER TEMPERATURE: MORE COMFORT LIVELLO COSTANTE DI TEMPERATURA DELL’ACQUA: MAGGIORE COMFORT NIVEL CONSTANTE DE TEMPERATURA DEL AGUA: NIVEAU CONSTANT DE TEMPÉRATURE DE L’EAU : COMFORT MAYOR CONFORT MAJEUR
10 EC INVERTER FANS EC INVERTER FANS Fans are electronically controlled by EC MOTORS = Electronically Commutated Motors that modulate the airflow regulating the fans speed VENTILATORI EC INVERTER I ventilatori sono controllati elettronicamente da MOTORI EC = Motori Commutati Elettronicamente che modulano il flus- so dell’aria regolando la velocità dei ventilatori proporzi onalmente in base alla carica di raffreddamento richiesta ed alla VENTILADORES EC INVERTER Los ventiladores son controlados electrónicamente por MO- TORES EC = Motores Modulados Electrónicamente modulan el flujo de aire ajustando la velocidad de los ventiladores VENTILATEURS EC INVERTER MOTEURS EC = Moteurs à Commutation Électronique modulent le flux d’air en réglant la vitesse des ventilateurs proportion nellement basé sur la charge de refroidissement demandée et HIGH EFFICIENCY MAXIMUM SILENCE
11 EC INVERTER FANS WITH HIGH AVAILABLE STATIC PRESSURE EC INVERTER FANS WITH HIGH AVAILABLE STATIC PRESSURE EC Inverter fans with SPECIAL TALLER DIFFUSER for higher efficiency VENTILATORI EC CON ALTA PREVALENZA UTILE Ventilatori EC Inverter con DIFFUSORE SPECIALE PIÙ ALTO per ef VENTILADORES EC CON ALTA PRESIÓN ESTÁTICA ÚTIL Ventiladores EC Inverter con DIFUSOR ESPECIAL MÁS ALTO por VENTILATEURS EC AVEC HAUTE PRESSION STATIQUE UTILE Ventilateurs EC Inverter avec DIFFUSEUR SPÉCIAL PLUS HAUT DUCTED INSTALLATION HIGHER EFFICIENCY MAXIMUM SILENCE
12 AQUALOGIK TECHNOLOGY …/ST VERSION - Built-in hydronic kit with: VERSIONE …/ST - Gruppo idronico integrato con: VERSIÓN…/ST - Grupo hidrónico integrado con: VERSION …/ST - Groupe hydronique intégré avec : > > > BENEFITS BENEFITS > > > > >
13 MICROCHANNEL TECHNOLOGY … /MC VERSION ALUMINIUM MICROCHANNEL condensing coils with innovative PARALLEL FLOW VERSIONE ... /MC Batterie condensanti MICROCANALE in ALLUMINIO con innovativo FLUSSO PARALLELO: SCAMBIO TERMICO ottimizzato per una VERSIÓN ... /MC Baterías condensadoras MICROCANAL en ALUMINIO con FLUJO PARALELO innovador: intercambio de calor optimizado para una VERSION ... /MC Batteries de condensation à MICRO-CANAL en ALUMINIUM avec un FLUX PARALLÈLE innovant: EXCHANGE THERMIQUE STANDARD (CuAl) MICROCHANNEL HIGH EFFICIENCY LOWER REFRIGERANT CONTENT REDUCED WEIGHT
14 FREE-COOLING TECHNOLOGY … /FC VERSION For efficient production of chilled water WITHOUT USING COMPRESSORS in case of low ambient PROCESS COOLING and Basic components: WATER/GLYCOL solution FREE-COOLING CIRCUIT with WATER COIL 3-WAY VALVE MICROPROCESSOR AIR AND WATER TEMPERATURE PROBES VERSIONE ... /FC SENZA L’USO DI COMPRESSORI in caso di bas RAFFREDDAMENTO DI PROCESSO e Componenti base: soluzione ACQUA/GLICOLE CIRCUITO FREE-COOLING con BATTERIA AD ACQUA VALVOLA A 3 VIE MICROPROCESSORE. SONDE DI TEMPERATURA ARIA E ACQUA VERSIÓN ... /FC Permite la producción continua de agua fría SIN USO DE COMPRESORES ENFRIAMIENTO DE PROCESO y CENTROS DE DATOS Componentes basicos: solución AGUA/GLICOL CIRCUITO FREE-COOLING con BATERÍA DE AGUA VÁLVULA DE 3 VÍAS MICROPROCESADOR SONDAS DE TEMPERATURA AIRE Y AGUA VERSION ... /FC SANS L’UTILISATION DE COMPRESSEURS REFROIDISSEMENT DE PROCESSUS et CENTRES DE DONNÉS Composants de base: solution EAU/GLYCOL CIRCUIT FREE-COOLING avec BATTERIE À EAU VANNE À 3 VOIES MICROPROCESSEUR SONDES DE TEMPÉRATURE AIR ET EAU
15 INVERTER ENERGY SAVINGS SCROLL COMPRESSOR LOWER AMBIENT TEMPERATURE HIGHER SAVING 80 Energy Saving with Free-Cooling / Risparmio energetico con Free-Cooling Ahorro energético con Free-Cooling / Économie d’énergie avec Free-Cooling 70 Potencia absorbida / Puissance absorbée kW 60 Absorbed power / Potenza assorbita STANDARD CHILLER 50 40 UP TO 30 -96% 20 10 FREE-COOLING CHILLER 0 15°C -14 -10 -6 -2 2 6 10 14 18 22 26 30 External ambient temperature / Temperatura ambiente esterna / Temperatura ambiente exterior / Température ambiante externe °C Example with constant cooling power, chilled water in/out 15/10 °C / Esempio con resa frigorifera costante, acqua refrigerata in/out 15/10 °C Ejemplo con potencia frigorífica constante, agua refrigerada in/out 15/10 °C / Exemple avec puissance frigorifique constante, eau glacée in/out 15/10 °C
16 INVERTER DOMESTICSCROLL HOT WATER COMPRESSOR UP TO 55°C Outlet Water T°C 55 50 45 40 35 30 25 20 -20 -15 -10 -5 0 5 10 15 20 25 30 35 40 Ambient Air T°C FOR PHOTOVOLTAIC SYSTEMS FOR BOILER REPLACEMENT
17 INVERTER DOMESTICSCROLL HOT WATER COMPRESSOR UP TO 55°C EXEMPLARY PLANT DIAGRAM / SCHEMA DI IMPIANTO ESEMPLIFICATIVO / ESQUEMA ILUSTRATIVO DE LA INSTALACIÓN SCHÉMA ILLUSTRATIF DE L’INSTALLATION COOLING/HEATING CIRCUIT CIRCUITO DI RAFFREDDAMENTO/RISCALDAMENTO CIRCUITO DE REFRIGERACIÓN/CALEFACCIÓN CIRCUIT DE REFROIDISSEMENT/CHAUFFAGE 2 2 12 9 11 10 5 1 14 M 13 3 4 9 DHW CIRCUIT 4 6 CIRCUITO DHW M 8 7 CIRCUITO DHW CIRCUIT DHW É obbligatorio impostare il termostato all’interno Es obligatorio colocar el termostato dentro del Il est obligatoire de régler le thermostat à l’intérieur 3 LEGENDA / LEGENDA / LEYENDA / LÉGENDE Heat Pump Pompa di Calore Bomba de Calor Pompe à Chaleur Regulating valve Valvola di regolazione Válvula de control Vanne de régulation Expansion vessel Vaso d’espansione Vaso de expansión Vase d’expansion Air separator Separatore d’aria Separador de aire Séparateur d’air Depósito de agua por DHW Réservoir d’eau pour DHW Termostato por depósito de agua por DHW Thermostat pour réservoir d’eau pour DHW Thermostatic valve Válvula termostática Safety valve Valvola di sicurezza Válvula de seguridad Soupape de sécurité System pump Pompa impianto Bomba instalación Pompe installation Serbatoio inerziale Depósito de inercia Réservoir tampon Water filter Filtro agua Filtre eau
18 INVERTER RANGE OVERVIEW SCROLL COMPRESSOR NEW NEW NEW VERSIONS / VERSIONI / VERSIONES / VERSIONS with Microchannel Solo raffreddamento avec Microchannel Solo frío Froid seul Pompa di calore reversibile Bomba de calor reversible Pompe à chaleur réversible KEY FEATURES / CARATTERISTICHE PRINCIPALI / CARACTERÍSTICAS PRINCIPALES / PRINCIPALES CARACTÉRISTIQUES INVERTER compressor INVERTER compressor 2021 2021 2021 Caratteristiche principali Características principales ErP SEER ErP SEER ErP SEER ErP SEER ErP SCOP ErP SCOP ErP SCOP ErP SCOP ErP SCOP 55°C 55°C 55°C 55°C Recuperatore di calore Con serbatoio e pompa Plate Plate Plate Plate Plate CuAl CuAl CuAl Livelli sonori Niveles sonoros Niveaux sonores
19 INVERTER RANGE OVERVIEW SCROLL COMPRESSOR NEW NEW VERSIONS / VERSIONI / VERSIONES / VERSIONS with Microchannel Solo raffreddamento avec Microchannel Solo frío Froid seul Pompa di calore reversibile Bomba de calor reversible Pompe à chaleur réversible KEY FEATURES / CARATTERISTICHE PRINCIPALI / CARACTERÍSTICAS PRINCIPALES / PRINCIPALES CARACTÉRISTIQUES INDOOR installation FREE-COOLING FREE-COOLING Open frame INVERTER compressor EC INVERTER PLUG-FANS 2021 Caratteristiche principali Características principales ErP SEER ErP SEER ErP SEER ErP SEER ErP SEER ErP SCOP ErP SCOP 55°C Recuperatore di calore Con serbatoio e pompa Shell and tube Plate Plate Plate Plate CuAl CuAl CuAl Livelli sonori Niveles sonoros Niveaux sonores
20 INVERTER RANGE OVERVIEW SCROLL COMPRESSOR VERSIONS / VERSIONI / VERSIONES / VERSIONS Solo raffreddamento Solo frío Froid seul Pompa di calore reversibile Bomba de calor reversible Pompe à chaleur réversible KEY FEATURES / CARATTERISTICHE PRINCIPALI / CARACTERÍSTICAS PRINCIPALES / PRINCIPALES CARACTÉRISTIQUES CONDENSERLESS CONDENSERLESS Caratteristiche principali Características principales ErP SEER ErP SEER ErP SEER ErP SCOP ErP SCOP ErP SCOP Recuperatore di calore Con serbatoio e pompa Plate Plate Shell and tube Plate Plate Plate Plate Shell and tube Livelli sonori Niveles sonoros Niveaux sonores
22 INVERTER TECHNICALSCROLL DATA COMPRESSOR CHA/IK/A 91÷151 plate exchanger piastre 91 91 101 101 131 131 151 151 A A A A A A A A A A A A A A A A A+ A+ A+ A+ A+ A+ A+ A+ A A A A A A A A mm mm mm mm mm mm CHA/IK/A 172-P÷574-P plate exchanger 172-P 172-P 192-P 192-P 212-P 212-P 232-P 232-P 272-P 272-P 302-P 302-P 352-P 352-P 372-P 372-P 484-P 484-P 574-P 574-P A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A+ A+ A+ A+ A+ A+ A+ A+ A A A A A A A A A A A A A A A A A A A A mm mm mm mm mm mm Reference conditions at page 19. Condizioni di riferimento a pagina 19. Condiciones de referencia en la página 19. Conditions de référence à la page 19. * Option. * Opzionale. * Opcional. * Optionnel.
23 INVERTER TECHNICALSCROLL DATA COMPRESSOR CHA/K/AF 182-P÷604-P R452B: CHA/G/AF 182-P÷604-P R454B: CHA/L/AF 182-P÷604-P 182-P 202-P 242-P 262-P 302-P 363-P 393-P 453-P 524-P 604-P A A A A A A A A A A A A A A A A A A A A A+ A+ A+ A+ mm mm mm CHA/K/A/WP 182-P÷604-P R452B: CHA/G/A/WP 182-P÷604-P R454B: CHA/L/A/WP 182-P÷604-P 182-P 202-P 242-P 262-P 302-P 363-P 393-P 453-P 524-P 604-P A A A A A A A A A A A+ A+ A+ A+ B C B B C B B B C C mm mm mm Reference conditions at page 19. Condizioni di riferimento a pagina 30. Condiciones de referencia en la página 30. Conditions de référence à la page 30.
24 INVERTER TECHNICALSCROLL DATA COMPRESSOR CHA/K 182-P÷604-P R452B: CHA/G 182-P÷604-P R454B: CHA/L 182-P÷604-P 182-P 202-P 242-P 262-P 302-P 363-P 393-P 453-P 524-P 604-P C C C C C B C C C B B B B B B B B B B B A+ A+ A+ A+ mm mm mm CHA/K 182÷604 R452B: CHA/G 182÷604 R454B: CHA/L 182÷604 182 202 242 262 302 363 393 453 524 604 C C C C C B C C C B B B B B B B B B C B A+ A+ A+ A+ mm mm mm Reference conditions at page 19. Condizioni di riferimento a pagina 30. Condiciones de referencia en la página 30. Conditions de référence à la page 30.
25 INVERTER TECHNICALSCROLL DATA COMPRESSOR CHA/K/E 252-P÷684-P 252-P 342-P 504-P 684-P C B C B mm mm mm CRA/IK/A 21÷131 and plate exchanger for indoor ducted installation e scambiatore a piastre per installazione da interno canalizzata y intercambiador de placas para instalación interior conducida 21 31 41 51 61 71 81 91 101 131 A A A A A A A A A A A A A A A A A A A A A+ A+ A+ A+ A+ A+ A+ A+ A+ A+ mm mm mm Reference conditions at page 19. Condizioni di riferimento a pagina 30. Condiciones de referencia en la página 30. Conditions de référence à la page 30.
26 INVERTER TECHNICALSCROLL DATA COMPRESSOR CHA/K/FC 91÷151 CHA/K/FC 91÷151 91 91 101 101 131 131 151 151 mm mm mm mm mm mm CHA/K/FC 91÷151 R452B: CHA/G/FC 91÷151 R454B: CHA/L/FC 91÷151 182-P 182-P 202-P 202-P 242-P 242-P 262-P 262-P 302-P 302-P 363-P 363-P 393-P 393-P 453-P 453-P 524-P 524-P 604-P 604-P mm mm mm mm mm mm Reference conditions at page 19. Condizioni di riferimento a pagina 30. Condiciones de referencia en la página 30. Conditions de référence à la page 30.
27 INVERTER TECHNICALSCROLL DATA COMPRESSOR CWW/K 15÷151 15 18 21 25 31 41 51 61 71 81 91 101 131 151 A++ A++ A+ A++ A++ A++ A++ A+ A++ A++ A++ A+ A++ A++ type Rotary Rotary Rotary Rotary Scroll Scroll Scroll Scroll Scroll Scroll Scroll Scroll Scroll Scroll mm mm mm CWW/K 182-P÷604-P R452B: CWW/G 182-P÷604-P R454B: CWW/L 182-P÷604-P 182-P 202-P 242-P 262-P 302-P 363-P 393-P 453-P 524-P 604-P mm mm mm Reference conditions at page 19. Condizioni di riferimento a pagina 30. Condiciones de referencia en la página 30. Conditions de référence à la page 30.
28 INVERTER TECHNICALSCROLL DATA COMPRESSOR CWW/K 182÷604 R452B: CWW/G 182÷604 R454B: CWW/L 182÷604 182 182 202 202 242 242 262 262 302 302 363 363 393 393 453 453 524 524 604 604 mm mm mm mm mm mm MEA/K 15÷151 15 18 15 21 18 25 21 31 25 41 31 51 41 61 51 71 61 81 71 91 81 101 91 131 101 151 131 151 type Rotary type Rotary Rotary Rotary Rotary Rotary Rotary Scroll Rotary Scroll Scroll Scroll Scroll Scroll Scroll Scroll Scroll Scroll Scroll Scroll Scroll Scroll Scroll Scroll Scroll Scroll Scroll Scroll mm mm mm mm mm mm Reference conditions at page 19. Condizioni di riferimento a pagina 30. Condiciones de referencia en la página 30. Conditions de référence à la page 30.
29 INVERTER TECHNICALSCROLL DATA COMPRESSOR MEA/K 182-P÷604-P 182-P 202-P 242-P 262-P 302-P 363-P 393-P 453-P 524-P 604-P mm mm mm Reference conditions at page 19. Condizioni di riferimento a pagina 30. Condiciones de referencia en la página 30. Conditions de référence à la page 30.
30 INVERTER TECHNICALSCROLL DATA COMPRESSOR LEGENDA / LEGENDA / LEYENDA / LÉGENDE COMPRESSOR / COMPRESSORE / COMPRESOR / COMPRESSEUR FAN / VENTILATORE / VENTILADOR / VENTILATEUR EXCHANGER / SCAMBIATORE / INTERCAMBIADOR / ÉCHANGEUR EC Inverter Plug-Fan / Plug-Fan EC Inverter / Plug-Fan EC Inverter Rotary / Rotativo / Rotativo / Rotatif Plate / Piastre / Placas / À plaques Plug-Fan EC Inverter Inverter Scroll / Scroll Inverter / Scroll Inverter / Scroll Inverter Shell and Tube / Fascio tubiero / Haz de tubos / Multitubulaire Scroll / Scroll / Scroll / Scroll Microchannel / Microcanale / Microcanal / À Micro-canal SOLUTION / SOLUZIONE / SOLUCIÓN / SOLUTION REFRIGERANT / REFRIGERANTE / REFRIGERANTE / RÉFRIGÉRANT Free-Cooling / Free-Cooling / Free-Cooling / Free-Cooling R410A AquaLogik / AquaLogik / AquaLogik / AquaLogik R452B A CLASS Cooling / CLASSE A raffreddamento R454B CLASE A frìo / CLASSE A refroidissement A CLASS Heating / CLASSE A riscaldamento CLASE A calor / CLASSE A chauffage NOTES / NOTE / NOTAS / NOTES Seasonal energy efficiency of cooling at low mento a bassa temperatura secondo il Rego dissement à basse température selon le Seasonal energy efficiency of heating at low Efficienza energetica stagionale di riscaldamen to a bassa temperatura in condizioni climatiche à basse température avec conditions clima climáticas medias de acuerdo al Reglamento giunge una resa frigorifera corrispondente a Temperatura aire ambiente en la cual se alcanza
Distributore Ufficiale Clint Climatica Group SA Via Industria 3, CH-6814 Lamone climatica.ch Tel. +41 (0)91 228 03 80 info@climatica.ch Via Max Piccini, 11/13 G.I. INDUSTRIAL HOLDING S.p.A. reserves the right to make changes in all specifications without notice. G.I. INDUSTRIAL HOLDING S.p.A. si riserva il diritto di modificare i dati qui riportati senza preavviso. 200CLD1630BAHD G.I. INDUSTRIAL HOLDING S.p.A. puede cambiar, sin preaviso, los datos existentes en este catálogo. G.I. INDUSTRIAL HOLDING S.p.A. se réserve le droit de modifier, sans préavis, les données actuelles.